Fireplace Installation
must be maintained. Ensure the
installation meets the national and
state/provincial electrical codes.
!
NOTE: It is recommended
that the bottom of the unit not be
mounted higher than 48" (1.22
m) from the ground to maintain
an optimized viewing angle of the
flame.
CAUTION: The fireplace must
be mounted at two points, one of
which must be on a wall stud.
WARNING: High tempera-
tures may be generated under
certain abnormal conditions. Do
not partially or fully cover or ob-
struct the bottom of this heater.
Bottom of unit must be a mini-
mum of 14" (356 mm) above the
floor or any surface such as a ta-
bletop to ensure adequate space
for heat exhaust from the bottom
of the fireplace (Figure 3).
3. With a wall stud finder, locate
the center of the wall stud,
drive a wood screw into the
stud and leave approximately
⅛" (3 mm) exposed threads
for the fireplace to hang on.
4. The second mounting point
should be picked such that it
is farthest (to the left or right)
relative to the first one among
8
Figure 2
A
B
C
D E F
H
the seven (7) keyholes (A to
G shown in Figure 2) on the
fireplace for wall mounting,
these keyholes are 2" (51
mm) apart. For example, if
you plan to use hole B as
the first mounting hole, the
second mounting hole must
be G.
Other available combinations
are A-G, C-G, A-F, A-E, A-D
and D-G.
5. Mark the second mounting
G
29¾" - 75¾"
(0.75 - 1.92m)
14" - 48"
(0.36 - 1.22m)
www.dimplex.com