Programming
the Water Softener.
POWER OUTAGE MEMORY
If electrical power to the water softener is lost,
"memory" built into the timer circuitry will keep
all settings for up to 24 hours. While the power
is out, the display is blank and the water softener
will not regenerate. When electrical power is
restored, the following will occur:
Reset the present time only if the display is
flashing. The HARDNESSand RECHARGE TIME
never require resetting unless a change is desired.
Even if the clock is incorrect after a long power
outage, the softener operates as it should to keep
your water soft. However, regenerations may
occur at the wrong time of day until you reset the
clock to the correct time of day.
NOTE: If the water softener was regenerating
when power was lost, it will now finish the cycle.
BLUE INDICATOR LIGHT
Steady blue light indicates that the unit is working
correctly. The light flashes when the unit needs
attention from the user.
• Light will also flash when power to until has
been interrupted. Check the PRESENT TIME
setting.
• Light flashes and DAYSTO EMPTYflashes -
check salt level and add salt as required.
• Light flashes and Err is in the display - electrical
problem with system.
LOW SALT SIGNAL
When the DAYSTO EMPTYdrops to 15, the blue
indicator light and DAYSTO EMPTYin the display
will flash every second and the alarm will beep
every 50 seconds (from 8:00 AM to 8:00 PM),to
notify the user that the unit is running low on
salt. As soon as any button is pressed, the alarm
will stop beeping. The blue indicator light and
DAYS TO EMPTYwill continue to flush. Once salt
is added to the brine tank and the SALT LEVEL is
reset, the DAYSTO EMPTYwill be reset.
ERROR SIGNALS
[
J /
If there is an error code
I-
I
1
detected, the blue
IZ I- !-
indicator light will flash 4
Call forServic
times every second, the
display will flash Err and
.
4t))
the alarm will beep every
50 seconds (from 8:00 AM to 8:00 PM) to signal
that the softener requires service. The alarm can
be turned off by pressing any button, but the blue
indicator light and display will continue to flash.
Disconnect the transformer from the wall outlet
momentarily, and plug it back in. The normal
display will appear. The motor may run for several
minutes, as the unit resets. If the problem is
not corrected, the error code will reappear in
8 minutes. See the Before you Coil for Service
section to assist in troubleshooting the water
softener.
21