Care And Cleaning; Service Position - GE GXSH4OV Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Care and cleaning.
ADJUSTING YOUR WATER HARDNESS
The blend adjusting knob (Figure 16) gives the
ability to finely adjust hardness of the treated water
leaving the water softener. If slightly harder water
is desired than is normally delivered by the water
softener, the blend adjusting knob can divert a small
stream of hard water and blend it with the soft water
entering the home. The amount of water diverted is
controlled by turning a blend adjusting knob on the
end cap of the valve stem.
NOTE:To get full performance from your water
softener leave blending valve in the factory closed
position.
To make adjustments to water hardness:
1. Hold bypass handle to keep the valve stem
from rotating (see figure 16). Loosen hex nut on
blend adjustment knob by turning the hex nut
counterclockwise.
2. TO INCREASE HARDNESS: With the bypass in
the service position (see figure 16) hold the handle
to keep the valve stem from rotating and turn the
blend adjusting
knob counterclockwise
up to 2
turns from the closed position.
It is recommended
that adjustments
be made in quarter turn
increments
over several weeks until the desired
hardness is achieved.
NOTE: Once an adjustment
is made to the blend valve knob the change in
water hardness at the homes faucets or shower
heads may take several days to be noticed. This
delay is due to the large amounts
of already
conditioned
water in the pipes and water heater
that must be exchanged
before a change in
hardness can be noticed.
Have the water tested
to determine
the actual water hardness.
3. TO DECREASE HARDNESS: With the bypass in
the service position (see figure 16) hold the handle
to keep the valve stem from rotating and turn the
blend adjusting
knob clockwise.
When the knob
will not turn anymore, hard water is no longer
being blended into the soft water.
/4. Once the desired hardness is achieved tighten the
hex nut (see figure 16) clockwise until it comes in
contact
with the bypass stem.
NOTE: To meet the water softener
performance
specifications
and reduction
of barium
and radium
claims the adjustable
hardness
must be kept in
the "OFF" position.
The off position
is achieved
when the blend adjusting
knob is fully rotated
clockwise
until it stops.
SERVICE POSITION
(Normal Softener Operation)
Soft Water
Pult
Out
Hard
Handle
]ter In
Stem
Softener./_
Valve Outlet
/
Diverted Hard Water
(Controlled by blend
adjusting knob)
Figure
16
Softener
Valve Inlet
Blend Adjus/_ting Knob
Turn counterdockw)se
to increase hardness of
treated water (clockwise
to decrease hardness)
Push
Handle
BYPASS POSITION
Hard Water
Out
Hard
Water In
Hex Nut
Turn clockwise to lock
blend adjusting knob
(counterclockwise to
unlock).
Figure 17
Blend Adjusting
K_nob
If serv)c)ng water
softener, turn dockw)se
as for as it will go.
,i I,CAUTION!
If the water softener is to be
serviced or disconnected from the bypass valve,
the blend adjusting knob must be turned all the
way clockwise to close the diversion path and
prevent water leaking from the softener valve inlet
of the bypass.
22

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gxsh45v

Tabla de contenido