2. At the back of the oven you will find cable "A" which is used to make the electrical
connection in this way:
Oven Wire Color
Black
White
Green/Yellow
WARNING: before starting to make any connections, check the following:
• that the mains voltage corresponds to the voltage indicated on the feature
identification plate B, figure 2.
• that the electrical mains the oven is to be connected to is powerful enough for
the maximum power the oven absorbs, indicated on the feature identification plate.
ELECTRICAL SPECIFICATIONS
Model
5HA-196 X
5HA-200 LX
5HA-200 RX
3. After it is plugged in, place the oven into the gap, taking special care not to leave
any surplus cable on top of the oven.
4. A switch must be placed in the most accessible site possible in order to
disconnect the oven, with a minimum of 3 mm between the contacts.
5. Fasten the oven to the unit with the 2 screws provided.
6. If the cooking function selector is not at position "0", turn it to "0" and set the time
on the oven( section 7.1).
House Wire Color
White (Neutral) & Green/Cooper
Volts
Watts
240
3,6 KW
B
-Figure 2-
11
Black (L1)
Red (L2)
(Ground)
Amps
15