Vimar ELVOX RS Serie Manual De Instalación Y Operación página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
Encoder connection:
Terminal number
Description
22
Motor 1 encoder signal input
23
Motor 1 encoder supply negative
24
Motor 1 encoder supply positive
25
Motor 2 encoder signal input
26
Motor 2 encoder supply negative
27
Motor 2 encoder supply positive
4.4- Connecting control buttons and key switch
Normally open contacts (the red AP/CH or APED LEDS light up when the selector or buttons connected in parallel are operated):
pedestrian opening control
opening control
4.5- Connecting photocells:
used then jumper between COM. and PHOTO and STPA, you must observe the polarity of the power supply for the photocells:
5
6
7
8
9 10 11 12
18
Led
encM1
ENCM1
22 23 24
SIG1 GND +V
13 14 15 16 17 18 19
Normally closed contact (when the photocells are not engaged the PHOTO LED and the STPA LED must be on), if not
13 14 15 16 17 18 19
+
- -
COM
FOTO
Encoder interface card
Led
encM2
ENCM2
25 26 27
SIG2 GND +V
Art. EDS1
COM
COM
N.O.
N.C. N.C.
N.O.
RX1
+
-
C NC NA
+
RX2
TX1
-
C NC NA
+
-
Fig. 6
TX2
+
-
Fig. 7
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido