6.4- Complete procedure for learning the travel for automatic gate systems with a single swing leaf, with encoder.
The complete procedure enables saving the travel, with the ability to customize the slowdown distance.
- Connect the motor to terminals 1 and 2 (output for motor M1), the control panel automatically configures itself for single leaf operation.
- Press learning push-button P2 and keep it pressed
- The DL6 LED starts flashing
- Do not release the P2 button and hold it down for another 2 seconds
- The DL6 LED starts flashing faster
- Release push-button P2
- Activate APCH: M1 closes at low speed until the mechanical stop
- Part M1 opening at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When M1 reaches full opening activate APCH or wait for the gate leaf to reach the mechanical stop
- The first gate leaf M1 closes at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When the gate leaf has completed closing, the DL6 LED will turn off to confirm successful programming.
N.B.: With this type of programming the mechanical stops are necessary when closing both during programming and in normal operation.
To program the travel without an encoder, remove the encoder interface card.
6.5- Rapid procedure for learning the travel for automatic gate systems with double swing leaf, without encoder.
The reduced procedure allows saving the travel, with distances for slowing down of 30% the total travel, while the gate leaf delays are fixed at 3 sec for
opening and 6 sec for closing.
- Press and hold learning push-button P2 for at least 3 seconds
- The DL6 LED starts flashing slowly
- Release push-button P2
- Activate APCH: M2 closes at normal speed until the mechanical stop
- M1 closes at normal speed until the mechanical stop
- M1 opens at normal speed until the mechanical stop
- M2 opens at normal speed until the mechanical stop
- M2 closes at normal speed until the mechanical stop
- M1 closes at normal speed until the mechanical stop
- The control panel performs a complete opening and closing cycle with the default slowdown distance and offsets.
- The DL6 LED will turn off to confirm successful programming.
With this programming the slowdown distance is set to 30% of the saved travel, the opening delay is 3 seconds and the closing delay 6 seconds.
N.B.: With this type of programming the mechanical stops are necessary both when opening and closing and during programming and in normal operation.
6.6- Rapid procedure for learning the travel for automatic gate systems with a single swing leaf, without encoder.
The reduced procedure allows you to save the travel, with slowdown distances of 30% compared to the total travel:
- Connect the motor to terminals 1 and 2 (output for motor M1), the control panel automatically configures itself for single leaf operation.
- Press and hold learning push-button P2 for at least 3 seconds
- The DL6 LED starts flashing slowly
- Release push-button P2
- Activate APCH: M1 closes at normal speed, until the mechanical stop
- M1 opens at normal speed, until the mechanical stop
- M1 closes at normal speed, until the mechanical stop
- The control panel performs a complete opening and closing cycle with the default slowdown distance.
- The DL6 LED will turn off to confirm successful programming.
With this programming, the slowdown distance is set to 30% of the saved travel.
N.B.: With this type of programming the mechanical stops are necessary both when opening and closing and during programming and in normal operation.