Trouble shooting
Problem
Possible.cause.
ON / OFF switch (5) is turned
off
Washer is
not opera-
Damaged power supply cable
ting
Mains fault
Air trapped in the pressure
Washer
washer
does not ge-
nerate any
Drop in the water mains
pressure
pressure
Severe
High-pressure nozzle (13) is
pressure fluc-
dirty
tuations
Spare Parts Order
When buying parts for the pressure washer, use the service address or fax number given.
Please enter your machine type and the product number of the part you are ordering.
Item. Description. .......................................................... Product.No.
14
Cleaning agent container with nozzle
13
High-pressure nozzle ...........................................................
1-2
High-pressure hose ..............................................................
12
Adjustable flat-jet nozzle ......................................................
11
Jet lance ............................................................................
10
Gun ..................................................................................
44
Remedy
Check ON / OFF switch
Check power supply cable (7) for
damage. If necessary have the power
supply cable (7) replaced by a quali-
fied electrician.
Check the electrical system for conformi-
ty with the data on the rating plate.
Turn on the washer with high-pressure
hose until bubble-free water flows out of
the high-pressure connection (3).
Check the water mains.
Rinse the high-pressure nozzle (13) with
water. If necessary clean the nozzle
hole with a needle.
...................................