encoder (default).
WARNING: Check that the impact force value measured at
the points established by the EN 12445 standard is lower than
that specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
10- Type of barrier (barrier) [1]
0: MOOVI 30RMM/60RMM mod. barrier
1: MOOVI 30S mod. barrier
2: BGV mod. barrier
Factory-preset value, in case of maintenance or malfunctions, check
the correspondence between the setting and the barrier model.
With the MOOVI 30RMM/60 RMM barrier (0) , the following func-
tions are not active:
- slow down
- torque setting (the barrier always works at maximum torque).
With the BGV barrier (2) , the following functions are not active:
- slow down
- torque setting (the barrier always works at maximum torque).
obstacle detection.
11.2) Logic Menu (logic. )
- TCA ( tca ) [ ON ]
ON
Activates automatic closing
OFF Excludes automatic closing
- 3 Steps (3 step) [ ON ]
ON
Enables 3-step logic. A start impulse has the following effects:
barrier closed: ...................................................................... opens
on opening: ........................ stops and enters TCA (if configured)
barrier open: ........................................................................ closes
on closing:...................................... stops and reverses movement
after stopping: ...................................................................... opens
OFF Disables 3-step logic
- Opening Impulse lock (Ibl open) [ ON ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening
- Impulse lock TCA (ibl TCA ) [ OFF ]
ON
The Start impulse has no effect during the TCA dwell period.
OFF The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (pre-alarM) [ OFF ]
ON
The blinker comes on about 3 seconds before the motor starts.
OFF The blinker comes on at the same time as the motor starts.
- Photocells on opening (photc. open) [ ON ]
ON: In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses
the motion only after the photocell is disengaged.
- Rapid closing (fast cls ) [ OFF ]
ON: Closes barrier after photocell disengagement, before waiting for
the end of the TCA (automatic closing time) set.
OFF: Command not entered.
- SCA Alarm (SCA alarm) [ ON ]
ON: The SCA contact (terminals 12-13) behaves as follows:
with barrier open and on opening:...contact closed (warning light on)
with barrier closed:contact open.........................(warning light off)
on closing:........................................ intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm
Time parameter.
- Master/Slave (Master) [ OFF ]
ON: The control panel is set as Master in a centralised connection (see
Paragraph 7).
OFF: The control panel is set as Slave in a centralised connection (see
Paragraph 7).
- Photocell test (test phot) [ OFF ]
ON: Activates photocell check (see Fig. 3)
OFF: Deactivates photocell check
- Electric edge test (test bar) [ OFF ]
ON: Activates electric edge check (see Fig. 3)
OFF: Deactivates electric edge check
-
Fixed code (fixed code) [ OFF ]
ON: The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF: The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
-
Radio transmitter programming (radio prog) [ ON ]
ON: This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1,
T2, T3 or T4) of a transmitter already memorised in standard mode
by means of the radio menu.
INSTALLATION MANUAL
2 – Within 10s press the hidden key (P1) and the normal key (T1,
T2, T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new
transmitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate
Radio menu.
11.3) Radio Menu (radio)
- Add start (add start)
Associates the required key to Start command
- Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the
key number (T1, T2, T3 or T4).
- Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
- Receiver code reading (RX code)
This displays the code entered in the receiver.
11.4) Language Menu (Language)
Allows you to set the language on the display programmer.
5 languages are available:
- ITALIAN (TA)
- FRENCH (FRA)
- GERMAN (DEU)
- ENGLISH (ENG)
- SPANISH (ESP)
11.5) MENU DEFAULT (DEFAULT)
Restores the preset default values on the control unit. After restoring, a
new autoset operation must be carried out.
phase.
11.6) DIAGNOSTICS AND MONITORING
The display on the LEO MV D panel shows some useful information, both
during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating which
device needs to be checked:
STRT
STOP = STOP input activation
PHOT
FLT
SWO
SWC
OPEN
CLS
BAR
TIME
In the case where an obstacle is found, the LEO MV D panel stops the
door and activates a reverse manoeuvre; at the same time the display
shows the "BAR" message.
11.7) Statistics
Having connected the Universal palmtop programmer to the control unit,
enter the CONTROL UNIT / STATISTICS menu and scroll the screenful
showing the statistical parameters:
- Board microprocessor software version.
- Number of cycles carried out. If motors are replaced, count the number
of manoeuvres carried out up to that time.
- Number of cycles carried out from the latest maintenance operation.
It is automatically set to zero after each self-diagnosis or parameter writing.
- Date of latest maintenance operation. To be updated manually from
the appropriate menu "Update maintenance date".
- Installation description. 16 characters can be entered for installation
identification.
12) CONNECTION TO PARKY CAR-PARK MANAGEMENT SYSTEM
The board is provided with an output (terminal JP4) for controlling the
barrier status, configured as follows (Fig.19):
contact closed between terminals 19 and 20 with barrier lowered
contact closed between terminals 18 and 20 with barrier raised.
13) SERIAL CONNECTION USING SCS1 BOARD (Fig.18)
The LEO-MV-D control panel allows several automation units (SCS1) to
be connected in a centralised way by means of appropriate serial inputs
and outputs. This makes it possible to use one single command to open
and close all the automation units connected.
= START
input activation
= PHOT input activation
= FAULT input activation for checked photocells
= input activation OPENING LIMIT SWITCH
= input activation CLOSING LIMIT SWITCH
= OPEN input activation
= CLOSE input activation
= input activation SAFETY EDGE
= TIMER input activation
MOOVI 30S-30RMM-60RMM Ver. 01 -
ENGLISH
19