Maintenance
Error
Item
code
10
EEProm
EEProm is currupt Entire system stops
Communication
Communication
lost
11
Master - Slave
+
Code 100=2
Communication
with additional
Communication
user interface
lost
12
(connected to
+
Rc-Rh-G2-Y2
Code 105.1=1
terminal blocks)
in zone 2
code 100=1
+
System
13
Communication
configuration
with slave board is
detected
HV
Communication
14
Communication
lost
with CDU
15
LWT
Value out of range
Code 100=1 +
code 105.0=2 or
Code 100=2 +
code 105.0=2 +
16
Zone control
code 105.1 = 2 or
Code 100=2 +
code 105.0=4 +
code 105.1 = 4
Backup heater is
active
EH temperature
+
34
warning
TWB does not
increase by 1°C
every 30 min
Code 133=1 or 2 +
LOW domestic
Domestic hot
hot water
water priority=1 +
*
temperature
Booster heater
warning
schedule OFF +
code 1.5=0
Code 133=1 or 2 +
Disinfection cycle
not completed
within time
Disinfection not
35
defined by code
succesful
143 or
Disinfection cycle
not performed
due to error 5.
Outdoor unit
should run in cool
mode
Configuration
36
+
Mismatch
Code 106.5=0 or
Unit is heat only
(80AWH)
Failure when
Entire system stops
No communication between unit and
interface.
Room temperature and humidity are
not available in zone 2
Unit runs with values stored in
memory
Entire system stops
Outdoor unit stops
Domestic water valve OFF if code
127=1
Outdoor unit stops
Domestic water valve OFF if code
127=1
Entire system stops
No effect on system operation
Domestic water tank electric heater
icon (
) will flash on user interface
screen
Domestic hot water is not produced
(unless code 1.3=1 or the diagnostics
is removed cycling power)
Entire system stops.
Consequences
Diagnostics and solutions
Check settings of codes 100, 103, 105,
106, 107.
If settings are correct, contact service.
Check wiring and connections
Check user interface wiring and
electrical connections
2 zone kit is installed.
Set code 100=2
Check sensor, wiring and electrical
connections
Change setting of code 105.
Check backup heater operation,
wiring and electrical connections.
Domestic hot water temperature is
cold and schedule prevents booster
heater activation.
User can activate booster heater
by setting code 1.5=1 (termporary
activation) or by enabling it in the
schedule.
Check code 140 to 144.
Check booster heater operation.
Check booster heater wiring and
electrical connections.
If code 127=2 check backup heater
operation.
Check domestic hot water
temperature sensor, wiring and
electrical connections
Modify setting of code 106.5.
Modify requested mode.
80AWX- 80AWH
33