Pin Assignment En - Abicor Binzel M-Drive MFS-V3 Instructivo De Servicio

Ocultar thumbs Ver también para M-Drive MFS-V3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Putting into operation
8 Set the contract pressure by turning the pressure lever (1).
9 Close the cover.
6.10 Pin assignment
1
1
Motor control lead jack X41
Fig. 10
Overview of the pin assignment
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Tab. 8
EN - 14
2
3
2
Control lead jack X46
Description
Speed sensor
Speed sensor
Speed sensor
Speed sensor
Speed sensor
Trigger
Trigger
Gas trigger
Gas trigger
CAT
CAT
CAT
Motor
Motor
n.c.
n.c.
Motor control lead
3
Digital wire actual value encoder X59
Signals
Gnd
Vcc
Stby
Ch A
Ch B
24 V
Switched back
GND gas valve incoming
GND gas valve closed back
Normally open switch
COM
Normally closed switch
Motor +
Motor -
M-Drive
X41 pin
a1
a2
a3
a4
a5
b1
b2
b3
b4
b5
c1
c2
c3
c4

Publicidad