Electronic timing thermostat
General characteristics
4 programs: MAN, P1, P2, P3
frost protection ( only with P3 )
manual operation
it is possible to program two different reference temperature values
(Tmin and Tmax)
indication of the time , day of the week, the ambient temperature, the
program chosen, and the on or off position of the load
floating battery for saving data in case of power failure. Duration: 30 days.
min time interval between two operations: 1 Minute
temperature field displayed: 5°C ÷ 40°C; updating with 1 minute intervals.
adjustable temperature values 7°C ÷ 35°C (with a min interval of one
degree)
tolerance for the temperature values: ± 0,5°C (once thermal state is
reached).
voltage
220/230V~ ±10% - 50 Hz
changeover contact 5A cosϕ 1; 2 A cosϕ 0,5, voltage free
max wire cross-sectional area: 2 x 2,5 mm
98
2
Tmin
ON
DAY 1
20
1
Tmax
OFF
1
MAN P3 COPY PRG
16
P
+
-
M
S
Tmin
ON
20
DAY 1
1
Tmax
OFF
1
MAN P3 COPY PRG
16
P
+
-
M
S
99