3997 - 3997C - 3997W - 3997WC
Tightness inspection
Hoses check
Make sure that connecting hoses (1 and 2) are in a good
condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions (3), they must be replaced.
When sticky materials are treated, check for possible clogging
along the hose (2), in the inlet (4) and on the baffle plate
inside the filtering chamber.
Scrape the inlet (4) from the outside and remove the
deposited waste as indicated in the figure.
Filtering chamber tightness check
If the gasket (5) between the container (4) and the filtering
chamber (3) fails to guarantee tightness:
■
Loosen the four screws (6) that lock the filtering chamber
(3) against the vacuum cleaner structure.
■
Allow the filtering chamber (3) to lower down and tighten
the screws (6).Replace the gasket (5) if the degree of
tightness is still not optimum.
■
Check the seal (2) for tightening between the cap (1) and
the filtering chamber (3).
The gaskets must be replaced if they are torn, cut, etc...
GB
C31
Figure 12
Figure 13
Vacuum cleaner disposal
Dispose of the vacuum cleaner in compliance with the laws in
force.
■
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The above symbol (Fig. 15), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damages to the environment or the health caused
by improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reuse of material resources.
Domestic users should contact the retailer or the local office
providing information on separate collection and recycling of
this product.
Companies should contact the supplier and check the
purchase contract terms and conditions.
This product can not be disposed of together with other
commercial waste.
14
Figure 15
01/2015