Operating Guidance; Reading Hold; Measuring Range Switch - koban KMD 03 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KMD 03
Digital multimeter
AC Current
Range
Resolution
400μA
4000μA
40mA
400mA
10A
Overload protection: μA and mA grade: Fuse F600mA/250V, A grade: Fuse
F10A/250V.
Frequency range: 50 ~ 60Hz
When measuring current is greater than 5A, the continuous measurement
time should not be more than 10 seconds. After measuring, disconnect the
current.

Operating Guidance

Reading Hold

• In the process of measurement, if reading hold is required, press "HOLD"
key, the value on the display will be locked.
• Press HOLD key again to cancel reading hold.

Measuring Range Switch

• When turning the conversion switch to current, voltage, resistance,
capacitance, frequency grade, the meter is in automatic measuring range
mode.
• Press "RANGE" key, the meter will enter the manual range mode. Ppress
once, the measuring range will go up with one grade. If it is pressed at the
highest measuring range, it will go to the minimum measuring range.
• If the user presses "RANGE" key more than 1 sec, the meter will restore
automatic measuring range.
Note:
Frequency and capacitance measurement can't be set to manual measuring
range mode.
Instructions manual |
28
0.1μA
1μA
±(1.5% of reading + 2 digits)
10μA
100μA
10mA
±(3.0% of reading + 5 digits)
Accuracy
www.grupotemper.com

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

T-rms kmd 01

Tabla de contenido