Technical Characteristics - Truper COMP-50LV Manual De Instrucciones

Ocultar thumbs Ver también para COMP-50LV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL CHARACTERISTICS:

Voltage:
120 V
Frequency:
60 Hz
Current:
15 A
Motor Rated Power:
2.5 Hp
Maximum
Motor Power:
3.5 Hp
Speed:
3 400 RPM
Maximum Pressure:
116 PSI
Air Flow:
4,4 CFM - 40 PSI
3,4 CFM - 90 PSI
Power Cord Grips Type: Y
All conductors are: 14 AWG x 3 C with 221 ºF insulating temperature
Insulation quality: Basic insulation.
Insulation quality: Class I
Thermal insulation of motor winding: Class B
CAUTION
To avoid risk of electrical shock or serious accident,
if power cord gets damaged it should be repaired by the
manufacturer or by Truper® Authorized Service Center
Power cord grips used in this product: Type"Y".
Assembly design in this product causes insulation to be affected
by liquid spills or splashing.
WARNING
Before gaining access to terminals,
all power circuits should be disconnected.
WARNING
We do not recommend using power
cord extensions with compressors. Using that type of
extension cause power drops resulting in motor potency
loss and overheating. Instead of using an extension cord increase
the compressor's action scope connecting a longer hose into the
outlet. Connect additional hose lengths as needed.
ELECTRIC CONNECTION
The unit is factory-equipped with cables. It shall be connected to
the corresponding power outlet. Connect the tool to a separate
power outlet. Double-check voltage and electric circuit current
matches the one corresponding to the motor. Use only cables with
the right diameter. We recommend using at least an 8 AWG cable
with 590.5" lengths maximum.
AIR CONNECTION
For the best use of the compressor connect the flexible hose to the
air circuit to isolate the unit's vibrations.
FIRST USE
1.
Verify the previous instructions have been carried out.
2.
Oftentimes when the compressor is shipped it contains a small
amount of oil. Fill up the compressor up to the red circle in
the oil level.
3.
Set the air filter (1) in the cylinder head (first, remove the
transport cap from the setting orifice).
4.
Remove the transport cap (with no orifice) and set the oil
deposit cap (5)
5.
Refrain from using electric extensions. If you must use them
unwind completely and use cables with enough capacity..
Turn on the compressor with the On/Of switch (9)..
At this moment the compressor is ready to function, unless
the air receptor is still under low pressure. (Gauge).
~
Turn off the unit while is running using the automatic pressure
switch button. The pressure switch will be ventilated and the
compressor will start again with no load.
PARTS LIST
1.
Air filter
2.
Work Pressure Gauge
3.
Tank Pressure Gauge
4.
Outlet Valve
5.
Oil Deposit Cap
6.
Regulating Knob
7.
Oil Level Indicator
8.
Tank Drain
9.
On/Of Switch
10. Safety Valve
3
10
5
1
9
7
6
4
2
8
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

19360

Tabla de contenido