Technical Data; Power Requirements - Truper COMP-AERO Manual Del Usario

Compresor de diafragma para aerógrafo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Maximum Pressure
Continuous Air Flow
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
To prevent electric shock, the tool shall be grounded while
in use. • Connect the plug into a correctly grounded outlet as shown in
example A. Not all the outlets are properly grounded. If in doubt, verify with a
qualified electrician. • If the outlet where you will connect the tool has two
poles (2 orifices). UNDER ANY CIRCUMSTANCE, DO NOT REMOVE OR
ALTER THE PLUG'S GROUND CONNECTOR. Use a temporary adaptor as
shown in example B and always connect the ground conductor lug as shown.
CAUTION
When using an extension cable, verify the gauge is enough
for the power that the tool needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and the motor will overheat. The following table shows the right size to use depending on cable's
length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use a
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
Code
Description
Voltage
Frequency
Power
Work Cycle
Cable length
Number of
Conductors
3 (one grounded)
COMP-AERO
17247
Airbrush Diaphragm Compressor
110 V
60 Hz
1/5 Hp
58 PSI
6 gal/min
5 minutes' work per 20 minutes' rest.
Maximum 3 hours daily.
5,2 ft
Power cord grips used in this product: Type "Y".
Tool Build: Class I
Thermal Insulation of Motor Winding: Class F
Authorized Service Center.
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
Output
¼-18-NPT
IP Grade
IP20
A
B
CAUTION
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

17247

Tabla de contenido