Technical Data

Code
Description
Voltage
Current
Measurements
Air Connections
Maximum Pressure
Air Flow
Tank Capacity
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
The equipment shall be grounded while in use
to prevent an electric shock.
• Connect plug into a properly grounded contact or outlet as shown in
example A. Not all contacts or outlets are properly grounded. If not sure,
contact with a certified electrician.
• If the outlet you want to use with the equipment has two poles (2 orifices),
FOR ANY REASON AT ALL DO NOT REMOVE OR ALTER THE PLUG'S EARTH
TERMINAL. Use a temporary adapter as shown in example B and always
connect the earth conductor's lug as indicated.
CAUTION
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower gauge
cable will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right size to use
depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
* It is safe to use only if the extensions have a built-in artifact for over current protection.
WARNING
When operating power tools outdoors, use a
"For Outdoors Use". These extensions are especially designed for operating outdoors and reduce the risk of
electric shock.
WARNING
All the cabling, power connections and the ground connection of the system shall be in
compliance with the Mexican Official Standard NORMA OFICIAL MEXICANA NOM-001-SEDE-2012,
INSTALACIONES ELÉCTRICAS (UTILIZACIÓN) or with the local codes and municipal by-laws.
127 V
9 A
15,9" x 17,3"
14 AWG x 3C with 221 °F insulation temperature
Class I
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class B
Number of
Conductors
3 (one grounded)
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
COMP-24S
13830
Oil-free air compressor
Frequency
Motor Power
Weight
1/4" fast coupling
135 PSI
3,4 CFM - 40 PSI
2,4 CFM - 90 PSI
6,3 gal
IP Grade
Authorized Service Center.
B
Extension Gauge
From 6 ft to 49 ft
|
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled
60 Hz
1-2/3 Hp
28,6 lb
IP20
A
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG