Caller Identification

Through caller identification: in this case the output is activated at ―cost-free‖ as the Communicator, after identifying the
caller, rejects the call and activates the output.
 Monostable OC outputs deactivate (switch OFF) automatically when the programmed ON Time expires.
 Only the T3 output of the BGSM-100 can be activated through Caller Identification.
The ON time may be set to a period of time between 1 and 86400 seconds, in steps of 1 second.
 The default User code is ‗0001'; if you wish to change it, please refer to the section ―Remote programming by SMS
message->Changing the User code‖.

REMOTE PROGRAMMING BY SMS MESSAGE

In addition to the processes described in the section Remote activation and deactivation of the outputs, it is also
possible to carry out other remote procedures through the transmission of various SMS messages.

Changing the user code

The default user code is ‗0001'; to change it, send an SMS message consisting of the characters ―#CUC‖ followed by the
old User code and the new User code between * characters, in accordance with the following formula:
You will receive an SMS confirmation if the User Code has been changed.
 The User code may only consist of numbers from 0 to 9 (maximum 4 digits).

Enabling or disabling remote programming

Remote programming makes it possible to use the functionalities of the BGSM-120/BGSM-100 Console software via a
network. In order to remotely manage the parameters of the Alarm Communicator, remote programming must be enabled.
This can be done using the BGSM-120/BGSM-100 Console software (see the Programming via PC->GPRS->Remote
Programming section), or by sending an SMS message consisting of the characters ―#UWS‖ followed by the User code
and ―ON‖ between * characters, in accordance with the following formula:
To disable the Remote Programming, send the following SMS message:
A text message will confirm whether the command was successful.

Changing the Installer code

The Installer Code (maximum 4 digits) is used for accessing the remote programming interface (see the Programming via PC-
>Codes->Installer Code section). The default installer code is ‗0002'; to change it, send an SMS message consisting of the characters
―#CIC‖ followed by the old Installer code and the new Installer code between * characters, in accordance with the following formula:
You will receive an SMS confirmation if the Installer Code has been changed.
 The Installer code may only consist of numbers from 0 to 9 (maximum 4 digits).

Credit balance check

To find out the credit balance via SMS, you can either use the BGSM-120/BGSM-100 Console software (see section
Programming via PC->Options->Pay As You Go), or you can find out remotely by sending an SMS message consisting
of the characters ―#CCC‖ followed by the * character, in accordance with the following formula:
 The balance SMS will be sent to the Telephone Number #1 of the Phonebook.
The pre-paid SIM CARD credit management service may be suspended at any time, at the discretion of each
individual GSM network operator.
16

(BGSM-120 series only)

#CUC*User code*New User code*
#UWS*User code*ON*
#UWS*User code*OFF*
#CIC*Installer code*New installer code*
#CCC*