Periodic voice
This section is used to program periodic voice message options.
You MUST enter the ―SIM Phone Number‖ and enable the ―Auto Clock Adjusting‖ in the ―Options‖ page to
setup the Periodic Voice's options.
Date of first send: Select the date on which the first periodic voice message is to be sent.
Time of first send: Select the time at which the first periodic voice message is to be sent.
Interval: Enter the interval (HH-DD) at which subsequent periodic voice messages are to be sent. The interval consists
of the following values:
– (HH) next message time - Select the hour value for the next periodic voice message. The interval for these values may
be set between 0 and 23.
– (DD) next message day - Select the day value for the next periodic voice message. The interval for these values may
be set between 0 and 365.
Update time: Select this icon to get local date and time from the PC.
Local Service Mode
By selecting the Local service mode button, you can enable the voice messages playing/recording by a touchtone telephone
connected to the [LI] terminals of the device (refer to ―Local Voice Message Recording‖ and ―Local Voice Message Replaying‖).
When this mode is enabled, the green LEDs L1 and L2 flash (see Status Leds->table 2). The LEDs only stop flashing when
the recording or replaying procedure is complete, or after 60 seconds have elapsed without any of the buttons being pressed.
You can connect ONLY ONE telephone to the [LI] terminals for proper working of the Local Service Mode.
SMS dialer (BGSM-120 series only)
This page is to setup the SMS dialer'options, as indicated following.
Event type: The ‗Event type' column has 11 separate lines listing the events for which two SMS messages are sent,
if programmed: one for activation and one for resetting (the "Periodic SMS" event only sends an activation SMS).
To select SMS messages for the 3 programmable input lines, set the corresponding terminal as an input
(see I/O->Type).
Telephone numbers: Click the ‗12345678' columns in accordance with the desired input. A tick indicates that the
SMS message will be sent to a particular telephone number when the corresponding event occurs.
The telephone numbers are the first 8 entries on the ―Phonebook‖ page.
SMS String: In the ‗SMS String' column, click the box corresponding to the message to be programmed and enter the
message you wish to send when the relevant event occurs (maximum 100 characters).
Periodic SMS
This section is used to program periodic SMS message options.
You MUST enter the ―SIM Phone Number‖ and enable the ―Auto Clock Adjusting‖ in the ―Options‖ page to
setup the Periodic SMS's options.
Date of First Send: Select the date on which the first periodic SMS message is to be sent.
Time of First Send: Select the time at which the first periodic SMS message is to be sent.
Interval: Enter the interval (HH-DD) at which subsequent periodic SMS messages are to be sent. The interval consists
of the following values:
– (HH) next message time - Select the time at which you wish to send the next periodic SMS. The interval for these
values may be set between 0 and 23.
– (DD) next message day - Select the day on which you wish to send the next periodic SMS. The interval for these
values may be set between 0 and 365.
Update time: Select this icon to get local date and time from the PC.
Voice Message (BGSM-120 series only)
This page can be used to record and replay the voice messages: refer to the ―Voice Dialer‖ page for massage association
to the events. To open the voice message archive, click the icon to the left of the RECORD button, on the right-hand side
of the field ―WAV File#1‖.
24