UNBLOCK IN CASE OF OBSTACLE
During the working, or during the Archimedean screw rotation or of the grater group, due to:
1. The introduction of food products with not homogeneous parts, as for example bones, or other,
2. The introduction of products excessively hard and dry, the machine could block, the machine could block.
The same situation can determine after an electric feeding break, or when the machine is stopped with inside the food product.
To be able to resume normally the working:
1. If the block is happened in the grinding group, this must be disassembled: the disassembly must not happen slacking the
blockage wheel, but slacking the grinding mouth block knob,
2. If the block is happened in the grater roll, the blocked food product must be removed manually.
CHAP. 5. DAMGES RESEARCH AND CLEANING
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the breaks or damages research and moving elements unblocking which can
be performed from maintenance men.
TYPE
POTENTIAL CAUSE/S
General Black out
Net voltage
Fuses or magneto thermals intervention
lacking
place upstream of the machine feeding
line
Protection device intervention inside
the machine
Functioning
intervention
Grater group handle lifting
Cause/s not identifiable
Feeding voltage lacking.
Sectioning devices set on "OFF".
The machine
Intervened fuses or not functioning
doesn't
magneto thermals.
function: the
Archimedean
Lacked running button functioning
screw or the
grater roll
don't rotate
Thermal intervention due to the
overheating
Damaged micro switch
CLEANING
It is forbidden to clean by hand the organs and the elements in motion.
All cleaning interventions must be started only and exclusively, after having unloaded the machine with the food product
in working and having insulated from the electric feeding source and from external energy.
The machine, the electric equipment and the machine board components must not be ever washed utilizing water, and not in
any kind of jets form and quantity; so, without "bucket" nor "rubber" nor "towel". Don't put ever directly the machine
in the sink or under the tap.
The machine hygiene level classification and the associated equipment, for the foreseen use, is 2 (two): machine that, after
an hygiene risk evaluation, is in conformance with applicable international standards requirements, but requests a programmed
disassembly for the cleaning.
MODALITY AND COMPARISONS
Contact the electric energy distributor
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Contact an electrician technician: after having eliminated the causes that have
determined the protection device intervention, restore it.
In case of fuses intervention, change them with types of the same model,
calibration and intervention curve.
Lifting the grater group pressure handle, the machine stops immediately for the
entry in function of the safety micro switch.
Lower the pressure up to the height that doesn't allow the fingers introduction
towards the grater roll and start the machine.
Contact directly the Authorized Assistance Center
Check and restore the electric energy.
Turn the sectioning devices in the position "ON"
Change the intervened fuses, check the magneto thermal switches state.
Check the START button efficiency and eventually contact directly the Authorized
Assistance Center.
Wait the complete cooling before the machine restarting
contact directly the Authorized Assistance Center