Appendix
Message Codes
All message codes will be displayed with either "InFo"
or "Error".
The following mistakes can be corrected:
InFo
Cause
204
Calculation error
252
Temperature too
high
253
Temperatur too low Warm up instrument
255
Receiver signal too
weak, measurement
time too long
256
Received signal too
powerful
257
Wrong measure-
ment, ambient
brightness too high
260
Laser beam inter-
rupted
Error
Cause
Hardware error
Stanley TLM 200 1.0.0 gb
Technical Data
Remedy
Repeat procedure
Cool down instrument
Use target plate
Use target plate
(grey side)
Use target plate
(brown side)
Repeat measurement
Remedy
Switch on/off the
device several times
and check if the
symbol still appears. If
so please call your
dealer for assistance.
5
Range (use target plate
from 70 m / 230 ft
onwards)
Measuring accuracy up
to 30 m (2 σ standard
deviation)
Smallest unit displayed
Laser class
Laser type
Ø laser spot
(at distance)
Automatic switch off
LCD-display
Illumination
Continuous Measuring
Calculation (+/-)
Battery life,
Type AAA, 2 x 1.5 V
IP rating
splash proof, dust proof
Dimension and weight
Temperature range:
Storage
Operating
0.05 m to 30 m
0.2 ft to 100 ft
typ.: ± 3 mm (± 1/8'')/
max.: ± 5 mm (± 1/5'')
1 mm (1/16'')
II
635 nm, < 1 mW
6 / 30 mm
(10 / 30 m)
after 180 s
up to 10 000
measurements
IP 54 acc. IEC529
135x55x34 mm, 160 g
-25°C to +70°C
(-13°F to +158°F)
-10°C to +50°C
(-14°F to +122°F)
Appendix