5. REMOVE THE PAN
Using a Phillips no. 2 screwdriver, remove the screws retaining the pan (shaded part
on illustration at right) to the hood. Remove the pan and set aside.
6. SELECT BLOWER OPTION
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 8, 10 to 13, then 15 and up of the present manual.
7. INSTALL THE NON-DUCT KIT FLUE ANKUP27M SERIES
Refer to the installation sheet included with the non-duct kit for details.

8. PREPARE THE CABINET

For cabinets with recessed bottom, attach two wood filler strips cut to length (not included), on each side, as shown below. See table below
for wood filler strips location.
H
Cut-out the openings for duct (A) and house wiring (120 VAC) (B) according to the blower option chosen. See figures below.
HOOD WITH INTERNAL BLOWER
HD0110A
(EXTERIOR OR INTERIOR)
(DUCTED INSTALLATIONS ONLY)
C
ENTER OF WOOD
OOD WIDTH
STRIP LOCATION
3
30"
13
3
36"
16
3
42"
19
3
48"
22
CABINET BOTTOM
3¼"
B
A
L C
4
5 8
"
Ø 8"
4"
8¾"
(A)
"
8
"
8
"
8
"
8
HD0208
HOOD WITH IN-LINE OR EXTERIOR BLOWER
4
"
5 8
91
"
8
5
7
HD0114
(NON-DUCTED INSTALLATION ONLY)
L C
A
A
CABINET BOTTOM
3¼"
B
A
L C
4
5 8
"
Ø 10"
5"
9
"
5 8
"
5 8
9
7
"
8