DGE− −ZR−RF
If the motor is turned around:
Note
When the motor is removed (e.g. turning the motor) the reference position is lost.
S Start a homing run as detailed in the chapter 6 Commissioning" in order to
set the new reference position.
8
Service and maintenance
Warning
Controller signals can cause the DGE to make unintentional movements.
S Switch off the controller for all maintenance work on the DGE and secure
it to prevent it from being switched back on unintentionally.
Do not adjust screws or threaded pins for which there are no direct demands
S
for modification in the operating instructions.
Lubricating the roller guide
Lubrication intervals: as needed, but theoretically no more than every
S
10000 km.
Note that lubrication must be undertaken more often in the case of:
S
dusty and dirty environments,
very short work strokes (running−in at one position).
Lubricate the DGE−...−ZR−RF at the lubrica
S
tion nipples on both sides of the slide.
Oil: e.g. Constant OY 390 from Klüber,
Grease gun: è Accessories chapter
If space is limited:
S Use lubrication adapter B (output axial)
or C (output radial) instead of the
standard lubrication adapter A.
52
:
Munich
A
B
C
Fig. 35
Festo DGE− −ZR−RF 0906d English