5.4 Perpendicular of Vertical Hair of Reticle of Telescope
Inspection
Adjustment
1. Fix the instrument on the tripod and perform precise leveling up.
2. Set a target point A 50 m away from instrument.
3. Aim the telescope at target point A and adjust the vertical fine movement. If
point A moves along the vertical hair of the reticle, no adjustment is required;
perform adjustment if the target point A strays from the vertical hair.
1. Remove the protective cover of the
reticle and slightly loosen the four
adjusting screws. Turn the assembly
so that point A coincides with the
vertical hair. Retighten the four
adjusting screws.
2. Repeat step 3. in "Inspection" and
step 1. in "Adjustment" until there is
no error.
T.O.2 | 33