Installation Of Front And Side Panels (Where Included); Control Panel And Functions; Setting The Water Temperature - Jacuzzi lodge MLS Manual De Instalación

Ocultar thumbs Ver también para lodge MLS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
-In general, when the hot tub is filled for the first time, the water
temperature is lower than the factory set value (35 °C), therefore
the heater and pump will be turned on at low speed - or the filtering
pump, where present (the control panel display will show the tem-
perature of the water in the tub).
- If the message "FLO" appears on the display, the pressure switch/
flow switch of the heater may be faulty. Please see chapter "Abnor-
mal operating conditions - Alarm signals".
Press the TEST button of the differential switch located up-
stream from the electrical system to which the hot tub is con-
nected. If it does not trip, it may be faulty or it may have tripped
due to problems in the electrical system of the building.
Disconnect the hot tub and do not use it until you have iden-
tified and eliminated the defect.
Check the operation of the pump (refer to chap. "Activation of
the hydromassage):
Check that the spotlights switch on and off using the key
"Light"
.
Check that the blower (if included) switches on and off using
the key "Blower"
.
Check that there are no leaks from the hydraulic connections
or other problems.
Completely disinfect the hot tub by carrying out "super-chlo-
rination" treatment.
Please refer to the Jacuzzi system water treatment guide
and relative catalogue for details on water quality mainte-
nance, the methods and warnings governing the use of rela-
tive chemical products.
After a few hours, turn off the omnipolar switch.
Open the drain valve(s) and completely empty the hot tub.
1
3
If included, re-install the front and side panels.
CAUTION
Do not use the hot tub the first time you start it as there
is a high concentration of chlorine in the water during
this phase. Immediately empty the bath.
Contact the local authorities for the standards govern-
ing the discharge of chemically treated water.
2
ø 40mm
1½"
4
26
Close the drain valve(s) and fill the hot tub again with fresh
water as previously explained.
Turn the omnipolar switch back on and check that the hot
tub works correctly.
Check and as necessary modify the water filtering cycles
based on how you intend to use the hot tub.
Installation of front and side panels
(where included)
Refer to the corresponding drawings. (

Control panel and functions

(
5) All hot tub functions are managed by the control panel on
the tub, as are the respective settings/programming.
NOTE Up/Down key
: if the display is equipped with a single "up/
down" key, the displayed value will increase upon holding down this
key; once the key is released, the scrolling direction will reverse (subse-
quently, upon holding down the key, the display value will decrease).

Setting the water temperature

The water is heated by a tubular electrical heater or by a heat ex-
changer. Do not set an excessively high water temperature, i.e. over
the limit of 40 °C. The recommended temperature is 35-36 °C.
NOTE: if the limitation of electric consumption is activated (see
relative chapter) and the switching on of the pump or the blower
turns off the heater (the led relative to the symbol
be turned on again, if necessary, 5 minutes after the pump or blow-
er is turned off.
Temperature unit of measure
The temperature scale is set to °C (Celsius). It can be changed to
°F (Fahrenheit) as follows:
Press and hold the key "Light"
you see the message "cFn" (if necessary use the key "Up/Down"
to scroll the menu until you come to "cFn").
Press the key "Light"
Now insert the password 123 as follows:
- use the key "Up/Down"
NOTE: hold the key down until you reach the desired value. If the
display is equipped with two separate keys, press the key "Up" to
increase the value or the key "Down" to decrease it.
- confirm the selection by pressing the key "Light"
Perform the same steps to insert the other two numbers.
Once you have inserted the password, the display will show the
message I1x (where "x" may be 1 or 0; the memorized value is 0).
Use the key "Up/Down"
responding to the scale in °F). Confirm the selection with the
"Light"
key. The display will show the message I2x.
2).
flashes) it will
for about 12 seconds until
again to confirm.
to select the first numeral.
.
to change "x" from 0 a 1 (cor-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lodge performance mls

Tabla de contenido