NOTES
- If a filtering cycles is active, it will restart 40 minutes after
the end of the stand-by condition at the same point it was
stopped. This means that if 1 hour remained when the cycle
was stopped, when it restarts it will operate for this amount of
time and then stop.
- If the heater was on when stopped, it is turned off immedi-
ately and water is circulated for 30 seconds in order to cool
the heating element.
I
ABNORMAL OPERATING CONDITIONS
ALARM SIGNALS
Alarms are indicated on the display, with the corresponding error
code. You will continue to see the code if the alarm condition persists.
Display Messages
- possible solution
"FLC" The flow switch detects water flow when there is
none (the heater is not turned on).
This may happen if the flow switch, which is connected in series
to the heater, is blocked by deposits or impurities that keep it
from operating properly. The flow switch may also be faulty.
- Contact an authorized Jacuzzi
"FLO" The flow switch does not detect the water flow (the
heater cannot be turned on).
The cartridge filter and/or pump may be clogged, or the flow
switch may have been installed in the wrong direction with
respect to the normal flow of water. If so, the internal contact will
not close. This will keep the heater from turning on.
The alarm may also appear if the flow switch is faulty.
- Contact an authorized Jacuzzi
"HOH" The measured temperature at the heater is 48 °C
(118 °F) or higher (the heater is turned off).
DO NOT ENTER THE WATER
This alarm, which is displayed alternating with the time and
temperature, will disappear as soon as the value drops below
44 °C (111 °F).
- If the alarm condition persists, try turning the switch up the line
from the spa off and back on. If the signal stays on, contact an
authorized Jacuzzi
®
service centre.
"Ho" Excessive water temperature.
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C (111 °F).
It is not possible to activate any function.
- If present, remove cover from spa.
- If the excessive temperature increase is due to sunlight, add cold
water to the spa.
When the temperature has dropped to below 43 °C (109 °F), the
spa should re-activate automatically. If it does not, disconnect the
power supply and contact an authorized Jacuzzi
®
service centre.
®
service centre.
®
service centre.
"rPF" Defective temperature probe.
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.
"HPF" Activation of safety thermostat.
It is not possible to activate the electric heater.
The electric heater has been deactivated due to overheating. This
may be due to irregular water flow.
- Try turning the switch up the line from the spa off and back on
(system reset). If the signal stays on, contact an authorized Jacuzzi
service centre.
PART TWO
INSTALLATION and MAINTENANCE
CAUTION
The operations described in part two must on-
ly be performed by qualified specialist per-
sonnel.
COMPONENTS and CONNECTIONS
The main components of the MaxiJacuzzi
1 Side panels
2 Pump
3 Electrical control box
4 Electric heater
5 Thermal cover
CAUTION
The thermal cover is not designed to support
weights. Do not sit, walk or lie on the cover. Do
not place objects on it.
PLEASE READ THESE INSTRUCTIONS THOROUGH-
LY BEFORE INSTALLATION
I
GENERAL WARNINGS
Any claims made after final installation for damages
that could have been identified and repaired before
installation are excluded from our warranty.
As the general sale conditions establish that return of the
goods is ex-works Valvasone (province of Pordenone), Jacuzzi
Europe S.p.A. accepts no liability deriving from damages sus-
tained during transport or intermediate warehousing. As soon
as you receive the MaxiJacuzzi
check that the packaging is in perfect condition and if not, im-
mediately notify the forwarding agent.
32
i
®
are (
2 and 3):
®
, it is therefore important to
®