RIB IDRO Serie Manual Del Usuario página 22

Operador oleodinamico para puertas batientes
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
M
ANUAL OPERATION WITH KEY - IDRO DUE 27
To release operate as follows:
- Insert the key and turn it about 180° anti-clockwise (Fig. 11).
To relock the operator do as follows:
- Insert the key and turn it clockwise until it stops (Fig. 11).
Attention: To release cut current supply.
M
ANUAL OPERATION WITH KEY - IDRO 39
Open the RIB cap.
Insert the key into the lock.
Turn the key 90° in anti-clockwise sense, without forcing it.
Then manually operate the gate by smoothly pushing the gate swing.
To reset automatic operation, set it to the initial position, remove the
key and close the cap to prevent water and powder from entering the
unlocking device.
WARNING: During manual operations be sure that the motor is off.
CAUTION: Models IDRO DUE 27R, IDRO DUE 27S/R and IDRO
39/R (reverse type) always feature the unlock mode. In
this case the unlock mode allows the adjustment (increase/
decrease) of stroke reversibility, to avoid undesired wing
gate movement in presence of wind.
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for
the operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390N for
doors/gates for commercial and industrial sites ( values indicated in
5.3.5 of the EN 12453 norm).
F
ORCE ADJUSTMENT (BY-PASS VALVES)
Use a screwdriver to increase the force by rotating clockwise the
opening valve (grey) and the closing valve (yellow) located below
the plastic valves cover (to remove) of the IDRO DUE 27 operator (Fig.
13) or below the cover (after You have unscrewed the 4 screws) of the
IDRO 39 operator (Fig. 14).
Decrease the force by rotating anti-clockwise the opening and closing
valves.
WARNING: When adjusting the force, smoothly and gradually rotate
the valves without screwing them or unscrewing them
completely.
We suggest to you to adjust the valves in a way that the pressions are
not different between themselves.
Adjust the opening pressure a little higher than the closing.
M
AINTENANCE
To be undertaken only by specialized staff after disconnecting
power supply.
Lubricate the hinges and check the oil level and thrust force generated
by the operator on the gate once a year.
IDRO DUE 27 - 27 SUPER
IDRO 39
IDRO DUE 27 - 27 SUPER
BY-PASS
VALVES
Take off the plastic valves-cover
IDRO 39
22
22
Lock
Release
11
12
13
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Idro due 27Idro due 27 superIdro 39

Tabla de contenido