Safety Information (continued)
ELECTRICAL SAFETY (EXTENSION CORDS)
(CONTINUED)
Ampere rating (on air compressor data plate)
0–
2.1–
2.0
3.4
Cord
Length
25 ft.
16
16
50 ft.
16
16
100 ft.
16
16
Used in 12 gauge – 20 amp circuit.
NOTE: Use longer air hoses instead of long extension
cords. Your air compressor will run better and last
longer.
ELECTRICAL SAFETY (ELECTRICAL
CONNECTION)
1.
This air compressor is powered by a precision built electric
motor. It should be connected to a power supply that is 120
volts, 60 Hz, AC only (normal household current).
2.
Do not operate this tool on direct current (DC). A substantial
voltage drop will cause a loss of power and the motor will
overheat. If the air compressor does not operate when
plugged into an outlet, double check the power supply.

ELECTRICAL SAFETY (SPEED AND WIRING)

1.
The no-load speed of the electric motor varies by model and
specification. The motor speed is not constant and
decreases under a load or with lower voltage. For voltage,
the wiring in a shop is as important as the motor's
horsepower rating.
2.
A line intended only for lights cannot properly carry a power
tool motor. Wire that is heavy enough for a short distance
will be too light for a greater distance. A line that can
support one power tool may not be able to support two or
three tools.
3.5–
5.1–
7.1–
5.0
7.0
12.0
Wire Size (A.W.G)
16
16
14
16
14
14
14
12
10
ELECTRICAL SAFETY (GROUNDING
INSTRUCTIONS)
1.
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
12.1–
providing an escape wire for the electric current. This air
16.0
compressor is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into a matching outlet that is properly
14
12
installed and grounded in accordance with all local codes
and ordinances
2.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
3.
The conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment
grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment
grounding conductor to a live terminal.
4.
Check with a qualified electrician or service personnel if you
do not completely understand the grounding instructions, or
you are in doubt as to whether the tool is properly
grounded. This product is
not use an adapter with this product.
4
l P
use on a nominal 120-V. Do
for
a e
e s
c
n o
a t
t c
- 1
8 8
- 8
D H
H -
U
K S
H
U
S
Y K
O T
O
S L
C .
O
M
f Y
r o
u f
t r
e h
a r
s s
s i
a t
c n
. e

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0300813a

Tabla de contenido