TECHNICAL DATA

Control unit power supply
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
CELL.P control unit with microcontroller
Terminals
1, 2, 3
4, 5, 6
7
8
9
10
11
12
13
14, 15
16,17
18, 19
1) Cut off power supply.
2) Manually release the door, move it at around half stroke and lock it again.
3) Reset power supply.
230 Vac
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1 motore230 Vac
1000 W
24 Vac, 7W max.
IP50
-20°C / +50°C
INPUT/OUTPUT FUNCTIONS
Function
Description
Input, 230VAC 50/60Hz
Power supply
(1-Phase/2-Neutral/GND-Ground connection)
Connection to motor:
Motor
(MOT-move/COM-Common/MOT-move)
LAMP
Output, connection to Flashing light: 230 Vac 40W max.
SWO
Input, OPENING limit switch (Normally Closed contact)
SWC
Input, CLOSING limit switch (Normally Closed contact)
Safety edge or photocell Input
DAS/ PHOT
See DIP-SWITCH 3.
CLOSE
Input, CLOSE key (N.C. contact)
COM
Common, all control inputs.
Input, OPEN key (N.O. contact).
It is possible to connect a timer for opening in time slots.
OPEN
Contact CLOSED:gate open, Contact open:normal opera-
tion.
24Vac
Output, 24Vac/400mA max accessory power supply.
Contact free from voltage, not insulated for the connection
of open gate indicator lamp.
SCA
Open contact with closed door leaf. Flashing light during
the door leaf movement. With open door leaf, the contact
is closed.
Antenna
Not Used