The red LED DL1 indicates the activation of inputs according to the legend hereunder:
STOP
on with fixed light
PHOT
rapid flashing
SWO
1 flash with 2-second interval
SWC
2 flashes with 2-second interval
By flashing slowly, the red LED DL1 also indicates that the unit is powered.
The green LED DL2 indicates the movement direction of the motor and the status of the gate according
to the legend hereunder:
OPENING
CLOSING
Open gate without TCA
Open gate with TCA
Closed gate
As indicated by the symbol shown, it is forbidden to dispose this product as normal urban
waste as some parts might be harmful for environment and human health, if they are disposed
of incorrectly. Therefore, the device should be disposed in special collection platforms or given
back to the reseller if a new and similar device is purchased. An incorrect disposal of the device
will result in fines applied to the user, as provided for by regulations in force.
SPECIFICATIONS
Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
LED DIAGNOSTICS
1 flash with 1-second interval
2 flashes with 1-second interval
on with fixed light
rapid flash
LED off
WASTE DISPOSAL
230 VAC 50/60 Hz (115 VAC 50/60Hz CP.MS5 115)
1 motor, 230 VAC (115VAC CP.MS5 115)
750 W
24VDC 200mA max.
IP 40
-20°C / +50°C
433.92 MHz, incorporated ARC (Advanced Rolling Code)
64
15