Dip-Switch Functions; Led Diagnostics - Beninca ZED24 Manual De Instrucciones

Ocultar thumbs Ver también para ZED24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
DIP 1 "TCA"
The automatic closure is enabled or disabled
Off: disabled automatic closure
On: enabled automatic closure
DIP 2 "Prelam."
Forewarning flashing light enabled or disabled
Off: disabled forewarning flashing light
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
DIP 3 "Braking"
Braking is enabled or disabled.
Off: disabled braking.
With the "SWO" opening limit switch, the motor stopping is delayed by 1 sec to allow a better opening.
With the "SWC" closing limit switch, the motor stopping is delayed by 1 sec to allow a better closing
On: Braking activated in the opening and closing phase. The motor stopping is delayed by 3 sec with respect
to the triggering of the opening and closing limit switches to allow the completion of the operation.
DIP 4 "P.P. Mod"
The operating mode of "P.P. Push button" and of the transmitter are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
DIP 5 "TORQUE"
The max torque available is selected with this Dip-Switch.
Off: Reduced torque in the closing phase.
This function increases the sensitiveness of the amperometric sensor during closure, thus increasing the
safety level of the system. Therefore, this function requires a perfectly balanced door, submitted to periodic
checking in order to avert any faulty triggering of the sensor.
On: Torque at regular operation.
DIP 6 "Cond."
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter have no
effect in the opening phase.
DIP 7 "VRall"
Motor speed selection in the braking phase
Off: Minimum braking speed .
On: Maximum braking speed .
DIP 8
N/A
The control system has a series of self-diagnostics LED's which allow to check all functions:
SW1 LED
It switches off when the SWO opening limit switch is triggered
SW2 LED
It switches off when the SWC closing limit switch is triggered
STOP LED
It switches off when the STOP push button is pressed
PHOT LED
It switches off when the photocells are not aligned or if obstacles are present
OPN LED
It switches on when the OPEN push button is pressed
CLS LED
It switches on when the CLOSE push button is pressed
PP LED
It switches on when the PP push button is pressed
PGM LED
It flashes to show the correct operation of the control unit.
5 quick flashes, followed by a pause, of LED PGM indicate the activation of the safety edge.