Beninca BULL 5M Manual De Instrucciones Para El Usuario página 10

Ocultar thumbs Ver también para BULL 5M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
POSITIONING OF THE FOUNDATION PLATE (FIG. 5-6)
It is very important to keep to dimension X shown in Fig.2. This value de-
pends on the type of rack used:
X = 11 mm for rack in nylon
X = 13 mm for rack in iron, 12x30mm
Preset a corrugated tube (Fig.2 -A) for the passage of power supply cables
and connection wires for the accessories.
Check that, at the end of the fitting, the foundation plate is perfectly parallel
with respect to the wing.
Fitting with screw anchors on cement base)
Through 4 "T" screw anchors in steel (not supplied), firmly anchor the
foundation plate to ground by means of 4 bolts "B" (not supplied). Use the
foundation plate as drilling template.
To facilitate the fitting of bolts, 4 holes are provided on the plate (ref. F).
Fix the geared motor to the plate by means of the 4 screws V (M10x70), with
the relevant plain washers R and knurled washers, as indicated in the figure.
Installation with cement
In this case, after providing for an adequate foundation hole, pour cement
on the plate, taking care of the plate level. Check that the threaded inserts
(I) for the fitting screws are clean and cement free.
Wait for the hardening of the cement.
Fix the geared motor to the plate by means of the 4 screws V (M10x70), with
the relevant plain washers R and knurled washers, as indicated in the figure.
Height adjustment of the geared motor
The height of the geared motor (10mm max) can be adjusted in height, with
respect to the foundation base, by 4 dowels G.
In this case, BEFORE fitting the geared motor to the plate, apply the 4
adjustment dowels G, by inserting the 4 nuts D in the special housings
located at the bottom of the geared motor.
Then adjust the 4 dowels by lifting the geared motor at the desired height.
Fix the motor by firmly tighten the 4 screws V4 (M10x70) and related flat
washers R and knurled washers Z, as shown in the figure.
POSITIONING OF THE LIMIT SWITCH BRACKETS (FIG.7)
Manually open the gate and leave a clearance from 1 to 3cm according to
the weight of the gate between the main door and the mechanical stopper
A. Fix the bracket to the limit switch S by using the grains G, so that the limit
switch microswitch F is pressed. The same operation should be repeated
with gate in the closing phase.
N.B.: The limit switch bracket should be positioned so that the gate can be
stopped without hitting the mechanical stopper.
HOW TO INSTALL THE MAGNETS
(BULL 5M.S - BULL 8M.S - BULL 8OM.S) FIG.8
The magnets are housed in special supports (fig.8-"A"). These magnets are
to be fitted to the limit switch brackets or the rack and cause the triggering
of sensors when they approach them.
Fitting onto the limit switch brackets
The bases are complete with hooking tongue allowing the fitting of the
magnets to the limit switch bracket supplied with the operator, as shown
in Fig.8-B.
SPECIFICATIONS
Power supply
Current drawn
Torque
Work jogging
Protection level
Operating temperature
Capacitor
Gate max. weight
Rack module
Opening speed
Noise
Lubrication
Weight
10
BULL 5M
BULL 5OM
1,3 A
23,5 Nm
12,5 μF
500kg
CASTROL LP2
AGIP BLASIA 100
10,6 kg
This type of fitting allows to rapidly adjust the position of magnets. After
calculating the correct distance, fix the support in the correct position by
means of a screw, so as to avert the moving of the bracket.
Fitting onto the rack
As an alternative, the supports can be fitted directly to the rack, by using
the slots shown in Fig. 8-C. This fitting mode does not allow for subsequent
regulations. It is therefore advised to make some trials with temporarily
fitted supports before carrying out the final fitting.
IMPORTANT: The correct distance of the magnet with respect to the
sensor depends on the installation characteristics. This space cannot be
preset and must be adjusted on a trial basis.
The distances regarding the triggering of the sensor (value X) with respect
to distance K of 3 and 35 mm, which are shown in Fig. 8 are only indicative.
In any case, distance K must not exceed 35 mm as a higher distance will
not allow the triggering of the magnetic sensor.
MANUAL OPERATION (FIG.9)
Should a power failure or malfunction occurs, to manually operate the
gate proceed as follows:
-
After inserting the customised key C, turn it anti-clockwise and pull
the lever L.
-
The gear motor is unlocked and the gate can be moved by hand.
-
To return to the normal operating mode, close the lever L again and
manually activate the gate until it is geared.
WIRE DIAGRAM (FIG.10)
For the wire connections of the system and to adjust the operating modes,
please refer to the Instruction Manual of the control unit.
In particular, the anti-crash device (encoder) should be adjusted ac-
cording to regulations in force.
Please remember that the device should be earthed by means of the
appropriate terminal.
Fig.10 shows wiring for a standard installation. Before proceeding to wir-
ing, check that the type of cables used is consistent with those required
for accessories.
Dimension H stands for the installation height of photocells. A clearance
between 40 and 60 cm is advisable.
Key of components:
1
Gear motor with incorporated BULL control unit
2
M4 rack, Nylon/Fe
3
Limit switch brackets
4
Photocells
5
Mechanical stoppers
6
Key selector or digital keyboard
7
Flashing light
8
Antenna
WARNING
The RC product insurance policy, which covers any injuries or damages
to objects caused by manufacturing defects, requires the use of Benincà's
original accessories.
BULL 8M
230Vac 50Hz
30%
IP44
-20°C / +50°C
M4
10,5 m/min
<70 dB
CASTROL LP2
13,4 kg
11,4 kg
BULL 8OM
2,6 A
34 Nm
16 μF
800kg
AGIP BLASIA 100
14,2 kg

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bull 5m.sBull 8mBull 8 m.sBull 5 omBull 5 om.sBull 8 om ... Mostrar todo

Tabla de contenido