filtEr cartridGE rEplacEMEnt

the filter cartridge for the vp-100-qc will
WARNING:
filter approximately 500 gallons; however,
filter cartridge life will vary depending on
usage and water conditions. at a minimum
you must change the filter cartridge annually
for best results. You should change the filter
cartridge as soon as possible if you notice
any change in flow, taste, color, or odor of
the water being filtered; these changes
indicate that the filter cartridge should be
replaced. You should also change the filter
cartridge as soon as possible after a boil water
advisory has been lifted. When replacing the
filter cartridge, you must use Everpure by
pentair filter model v-500. failure to use the
filter model specified voids all claims and
warranties made in this manual. the system
no longer qualifies as nSf certified if you fail
to use the model number indicated.
notE: read all instructions before replacing filter cartridge.
notE: do not use petroleum jelly to lubricate the o-rings. it
will degrade the o-rings.
the rubber o-ring provides the water-tight
WARNING:
seal between the filter cartridge and the
filter head. it is important that the o-ring be
properly seated in the grooves or a water leak
could occur.
this filter system is designed and tested to
WARNING:
protect your drinking water before and during
a boil water advisory notice. after a boil
advisory has been discontinued and your water
supplier has deemed the water safe to drink,
discontinue use of the filter system, remove,
and discard the used filter cartridge, sanitize
the unit and install a new filter cartridge.
For replacement filter cartridges, see the dealer from whom
you purchased the system or contact Pentair at
800-279-9404 for the dealer nearest you.
cartridGE rEplacEMEnt - routinE
SErvicE
the following instructions are for servicing the unit and for
routine filter cartridge changes. if you are replacing the filter
cartridge on a schedule because of normal use:
a. turn off the water supply and open the faucet to
relieve pressure.
B. unscrew the filter cartridge and discard it.
C. refer to Step 7. install, Condition and Flush Filter Cartridge.
8 • EvErpurE
ViruPure™ VP-100-QC Multi-Stage Water Filtration System
®
cartridGE rEplacEMEnt -
contaMinatEd WatEr SupplY/Boil
alErtS
When the water system has been contaminated or a boil
water advisory has been discontinued, the VP-100-QC system
must be sanitized. if a boil water advisory has just been
discontinued: Flush the household water lines according to
your water supplier's instructions. open the delivery faucet
and flush the system for about 10 minutes, then follow the
filter cartridge replacement instructions below.
a. turn off the water supply at the angle stop valve and open
the faucet to relieve pressure.
B. unscrew the filter cartridge. avoid touching the used filter
cartridge and discard it in household trash. Wash hands
with soap and warm water.
notE: if a drip pan is used, clean with dish soap and
warm water.
notE: the following steps require placing household bleach
into the vp-100-qc system. Everpure by pentair
offers a hollow cartridge that is designed for this
application. visit www.everpure.com to purchase the
cartridge. the following steps describe how to use
that Everpure by pentair Jt cartridge (Ev9608-15).
Sanitization procedure - the Everpure
Jt cartridge (Ev9608-15)
C. grasp the tip of the outlet tower center, top of the cartridge
and pull out gently. the entire central plug with the long
tube attached will come out, leaving a hole.
d. add about a teaspoon of laundry bleach (5.25% sodium
hypochlorite solution) to the empty flushing cartridge
through the hole in the top.
e. lubricate o-ring with a high quality silicone lubricant.
replace the central plug assembly and insert the flushing
cartridge into the installed head.
notE: do not use petroleum jelly to lubricate the o-rings. it
will degrade the o-rings.
F. after inserting the flushing cartridge into the head and
opening the angle stop valve before the system, slowly
open the product water line and run water to drain until
the smell of chlorine is strong. then immediately shut off
the water and wait a period of at least half an hour to allow
adequate disinfection time.
g. the water should then be run for five minutes to purge the
installation of chlorine.
H. remove the flushing cartridge and insert a new everpure
by Pentair V-500 filter cartridge.
i. refer to Step 7. install, Condition and Flush Filter
Cartridge.
by pentair
®
d