FILTER CARTRIDGE REPLACEMENT

A) (1) Turn off water supply to filter. (2) Depress red pressure-relief
button to release trapped air. (3) Remove bottom of housing.
NOTE: If turning off water supply to the filter will also turn off water
supply to the rest of the home, be sure to fill a bucket of water first to
allow you to clean the housing after it has been removed.
B) (4) Locate and remove large O-ring, wipe clean of lubricant and set
aside. (5) Discard used cartridge. Rinse out bottom of housing and
fill about 1/3 full with water. Add about 2 tablespoons of bleach
and scrub cap and bottom of housing with nonabrasive sponge or
cloth. Rinse thoroughly. Check O-ring for damage. If cut, scratched,
or stretched, replace it with a new one. If the O-ring is in good
condition, (4) lubricate it with clean silicone grease, insert it back into
groove and smooth into place with finger.
NOTE: This step is important to ensure proper housing seal. Make
sure O-ring is seated level in the groove.
(5) Insert new cartridge over standpipe in bottom of housing.
C) (6) Screw bottom of housing onto the cap and hand-tighten.
DO NOT OVER-TIGHTEN. Make certain cap standpipe slips into
cartridge. (7) Turn on water supply slowly to allow filter to fill with
water. (8) Depress red pressure-relief button to release trapped air.
Flush cartridge for 10 minutes or according to cartridge instructions
before use.
Check for leaks before leaving installation.
NOTE: After installation, flush the cartridge for 10 minutes or according
to cartridge instructions before using the water.
NOTE: Use only genuine OMNIFILTER replacement cartridges for best
results. Failure to use OMNIFILTER replacement cartridges will void
your warranty.
TROUBLESHOOTING
Leaks between cap and bottom of housing:
1. Turn off water supply and press the red pressure-relief button.
Remove bottom of housing.
2. Clean and lubricate O-ring with silicone grease. Also, clean the
groove where the O-ring seats. Place O-ring back in groove below the
threads. Screw bottom of housing onto cap and hand-tighten.
DO NOT OVER-TIGHTEN.
NOTE: Replace O-ring if leak persists or if O-ring appears worn or
damaged. Replace O-ring every two years.
3. Turn on water supply. If leak persists, or if there are other leaks on the
system, turn off water supply. Call OMNIFILTER Customer Service at
800.279.9404.
Leaks on inlet/outlet connections:
1. Turn off water supply. For brass fittings, tighten nut snugly about
1/2-turn with a wrench.
2. Turn on water supply. If leaks persist, or if there are other leaks on
system, turn off water supply. Call OMNIFILTER Technical Support
at 800.279.9404.