Fireplace Installation
Option #1 - The power cord can
be lead from behind the trim
and along the wall to an outlet
near the fireplace.
Option #2 - A new outlet can be
installed inside the new frame
construction. Plug the unit into
a 15 Amp/120 Volt outlet. If
the cord does not reach, you
may use an extension cord
rated for a minimum of 1875
Watts.
Option #3 - Hardwire
1.
Wire a dedicated, properly
fused circuit with 120 Volt,
15 Amp rating. Allow up to
eight (8) feet of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION: Use two
conductor, non-metallic sheath
cable with ground wire (3 wires
total) for the incoming power
supply on fireplace inserts. use
appropriate wire to meet local and
national electrical codes for rated
power consumption.
2.
remove the outer jacket and
strip the individual conductor
from the end.
Figure 2
Figure 3
3.
Loosen the screw securing
the junction box cover and
remove the cover.
4.
Take the cables out from the
junction box, loosen the two
wire twist nuts and remove
the cord set (Figure 2).
5.
Route the power supply wire
through the knockout on
supplied alternative junction
box cover and secure with
9