Airflow Selection and Adjustment

Air flow direction adjustment
The airflow path may be adjusted to distribute air independently from the
left or right side of the discharge opening. Each of the banks of louvers
can be directed left, right, up or down in order to achieve the most optimum
airflow positioning.
To adjust airflow direction grab the lever in the center of the louver
bank and move it in the direction that you would like the air to be
directed. Please note that it is normal that airflow may be stronger
out of one side of the louvers than the other.
Installation Instructions
This section includes installation instructions for window mount
NOTE:
and thru-the-wall mount methods. Kühl heat/cool units are
designed for permanent thru-the-wall installation. Mounting the
unit in a window will require a window accessory kit, available
through your Friedrich dealer.
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner's
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Unplug unit prior to performing any service.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
READ THIS FIRST! Electrical Requirements
14
Figure 11
LEFT AIRFLOW
LEVER
IMPORTANT: Before you begin the actual installation of the air conditioner,
be sure your electrical requirements are as described below. Consult an
electrical professional as necessary to insure home wiring is per local
electrical codes.
CIRCUIT PROTECTION – An overloaded circuit will invariably cause
malfunction or failure of an air conditioner, therefore, it is necessary that the
electrical protection is adequate. Due to momentary high current demand
when your air conditioner is started, use a "TIME DELAY" fuse or a HACR
type circuit breaker. Consult your dealer or power company if in doubt.
Your air conditioner must be connected to a power supply with the same
A.C. voltage and hertz as marked on the unit nameplate. Only alternating
current (A.C.), no direct current (D.C.), can be used.
The power cord has a plug with a grounding prong of approved type
and a matching plug receptacle with ground is required. Refer to page
5 for the correct type of plug receptacle for your model.
RIGHT AIRFLOW
LEVER
FRR083