Figure 32
3/4" MINIMUM
SLEEVE FRONT
1" THICK LUMBER
1" MINIMUM
INSIDE WALL
EXTERIOR WALL
STEP 7.
Cut two pieces of standard 1" lumber (supplied by installer)
to the length and width required. Place in front and back of
bottom sill channel as shown in Figure 32. Secure with nails
(supplied by installer).
STEP 8.
Seal all holes in the sleeve with caulking compound (supplied
by installer). (See Figure 33)
Figure 33
SOLID MASONRY CONSTRUCTION
NOTE: ELECTRICAL RECEPTACLE LOCATION
FROM POINT "X" MUST BE WITHIN A MAXIMUM
RADIUS OF 69" FOR 115V UNITS.
FRONT EDGE OF LOUVERS
MUST ALWAYS BE OUTSIDE OF
EXTERIOR WALL SURFACE.
1/4" SLOPE DOWN.
POSITION AND SECURE
SLEEVE DOWNWARD.
SLOPE OUTSIDE FOR
DRAINAGE.
MAX. WALL
THICKNESS
ALLOWED 8-1/2"
CABINET
MORTAR
3/4" MINIMUM FRONT
EDGE OF SLEEVE TO
INSIDE WALL SURFACE.
1 1/4" SCREWS (F IN PARTS LIST) / 3 EA. SIDE
NAILS MAY BE USED IF DESIRED.
STEP 9.
Complete the installation by following STEP 5.3 (Page 18)
and STEP 8 (Page 19) of Standard Window Installation.
R1 Insulation panels and Window seal gasket mentioned in
STEPS 6 - 7 will not be required.
IMPORTANT: Before operating your unit, read CIRCUIT PROTECTION
of Standard Window Instructions, under STEP 8.
CAULK ALL SIDES
POINT "X"
TRIM AROUND THE
SLEEVE WITH A
SUITABLE WOOD
MOULDING AND
FINISH TO SUIT.
CAULK ALL AROUND
SLEEVE ON OUTSIDE
TO INSURE A WEATHER
TIGHT SEAL.
FRR092
ELECTRICAL
RECEPTACLE
FRR093