4. Match the thin, low-voltage RED, BLACK and
WHITE wires coming from the REMCON relay
cylinder to low-voltage wires in the fixture
outlet box. All wire connections must be securely
made. It Is recommended that tape be used for
connection. Where wire nuts are used, stagger
the connection. Then, slip the relay through the
proper knockout. Spring clips on sides will hold
the relay securely in place.
5. Connect the high-voltage line to relay and fixture.
6. Attach switch assembly plate to switch mounting
bracket. Pull 3 conductor #18 wire through
wall opening and connect securely to the
three terminals of the switch. Terminals are
marked RED, WHITE, and BLACK. Just match
the thin low-voltage wires to the colored switch
terminals. Then snap switches firmly into switch
assembly plate. (Plate is marked for 1, 2 or 3 gang
switches.) There is no restriction on the number of
switches that can be hooked up to the same relay.
7. Attach switch plate with screws provided,
making sure that ON is on top. When installing
the clear plastic switch plate be sure to insert
gold-tone card.