R-115S / RC-120S INSTALLATIONS
1. Turn off AC power to circuit which you will be
wiring the R-115S or RC-120S into (using fuse or
circuit breaker).
2. Mount R-115S or RC-120S relay in a metal box
near the load to be switched as shown in section
"Installing in A Metal Box" on page 9.
3. Connect control wiring (light-guage wires) to
R-115S or RC-120S.
4. Connect AC power wiring and load wiring to
R-115S or RC-120S as shown in diagram.
�CAUTION
• Refer to the safety information on page 3
before applying AC power to the REMCON
R-115S or RC-120S circuit.
• Improper connection of power leads will
result in permanent damage. Re-check your
wiring before turning on AC power to line.
5. Restore AC power to line.
6. R-115S: When control switch momentarily
connects white control to red control wire,
power to load is turned ON. When control switch
connects white control wire to black control wire,
power to load is turned OFF. Contact state of the
R-115S is maintained even if AC power to the
relay is lost and is then restored.
RC-120S: When control switch terminals are
closed, power is ON.