Programming the operator
14
Control elements
The controls for programming the door operator are
protected by a transparent cover. The transparent
cover can be opened with a screwdriver.
After the operator has been programmed, the
transparent cover must be closed again.
A. Numerical display shows the menu stage as well
as the selected value.
a. Point display, lights up to indicate "ready for
operation" and flashes on the hand transmitter code
learning completion.
a. Punktanzeige, leuchtet bei Betriebsbereitschaft
und blinkt bei Quittierung von eingelernten
Handsendercodes.
B. Button
during the setting / adjustment phase
serves as an "up" button and outside the menu as
a start button.
C. Button
during the setting /adjustment phase
serves as a "down" button.
D. Button
is used to call up the setting/adjustment
menu, to change the menu stages and to store the
Settings.
The programming of the control unit is menu-driven.
By pressing button
, the menu guide is called up.
The numbers displayed indicate the menu stage.
After approx. 2 seconds, the display flashes and the
setting can be altered via buttons
selected setting is stored with button
programme jumps automatically to the next menu
stage. By repeatedly pressing button
stages can be skipped. To quit the menu, press
button
until "0" is shown again. Outside the menu,
button
can be used to generate a start impulse..
Before programming
- Allow door to engage into the carriage.
- Pull out the mains plug. Point display (a) lights up.
- Make sure that the aerial is correctly positioned
(see figure 13).
- Observe the hand transmitter instructions.
15
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button
.
"1" is displayed.
Sas soon as the display flashes, press and keep
pressed for approx. 1 second the button of the hand
transmitter, with which you later wish to start the
operator.
As soon as the code has been read, the red point
display (a) flashes five times before quitting.
Further hand transmitters (up to a maximum of 10)
can be programmed.
16
Menu stage 2: Programming the light
function for the hand transmitter
Press button
.
"2" appears in the display.
Note: If no 4-minute light is to be programmed,
repress button
. The display shows "0" -
programming is completed.
Press the second button on the hand transmitter,
witch which the 4-minute light is to be switched on.
As soon as the code has been read, the red point
display (a) flashes five times before quitting.
After the code has been learned, briefly press
button
.
"0" appears indicating that you have come to the end
of the menu.
Deleating all the hand transmitters programmed
for the operator:
Plug in the operator 's main plug while pressing
button
.
17
.
Menu stage 3: Setting/adjusting the top
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
end-of-travel position
Keep button
pressed for 5 seconds. Number 3
appears in the display 14 a..
Wait a short while until the 3 starts flashing.
Press button
and make sure that the door travels in
the OPEN direction.
If the door travels in the wrong direction CLOSE,
keep button
!
"3" flashes briefly. The travelling direction is
Altered.
Now travel by pressing button
end position OPEN 17b.
By pressing button
into direction CLOSE.
Once the desired OPEN end-of-travel position has
been reached, press button
the OPEN end-of-travel position and "4" appears in
the display.
18
Menu stage 4: Setting/adjusting the bottom
end-of-travel position
Wait a short while until "4" starts flashing.
Press button
. The operator causes the door to
travel in the CLOSE direction as long as the button is
pressed. The position can be altered to the OPEN
direction via button ..
Once the desired CLOSE end-of-travel position has
been reached, press button
the CLOSE end-of-travel position and "5" appears in
and
. The
. And the
the display.
Press button
twice until "0" appears..
, menu
18a
Force-learning cycle
We recommend setting the suitable door type in
!
menu stage 8 prior to the force-learning cycle.
During this opening and closing cycle, the
operator learns the force required to open and close
the door. A forcel imit does not apply! The cycles
must not be interrupted. During these cycles must
not be interrupted. During these cycles "0" appears
in the display.
- Press button . The operator causes the door to
open until the top end-of-travel position has been
reached.
- Now press button
the door to close until the bottom end-of-travel
position has been reached.
- After approx. 2 seconds, "0"disappears.
19
19
Menu stage 5: The opening force limit
If you have previously quit the setting menu, press
button
for 3 seconds until "3" appears. Then press
button
twice until "5" appears..
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
setting can be increased for decreased via buttons
and .
After setting the value, press button
The display shows "6".
20
Menu stage 6: The closing force limit
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons
and .
After setting the value, press button
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Caution! If the force setting is too high, persons may
be placed at risk of injury.
The factory setting is 4!
pressed for another 3 seconds.
into the desired door
, the position can be corrected
. The operator stores
. The operator stores
again. The operator causes
.
. "0" appears
21
Checking the force limit facility
- Place an obstruction (e. g. operator's cardboard
box) underneath the doors's closing edge.
- Starting from the OPEN end-of-travel position,
actuate the door to close.
- The door travels towards the obstruction, stops and
travels back to the top end-of-travel position.
- The point display (a) must switch off for approx. 1
second. Then the operator functions as normal
again.
If the door springs have been changed or altered,
then the force learning cycle must be repeated:
proceed to menu stage 5 and keep button
for 3 seconds. "0" appears in the display. Then
complete the force learning cycle as explained under
point 18a.
Special settings
Menu stage 7: Light phases
Press button
for 3 seconds.
"3" appears in the display. .
Press button
several times until menu stage 6 is
shown.
Keep button
pressed again for 3 seconds until
"7" appears in the display.
Menu Light phase
Warning
Value
phase
0
60 s
-
1
90 s
-
2
120 s
-
3
240 s
-
4
0 s
3 s
5
0 s
3 s
6
90 s
3 s
7
90 s
3 s
8
0 s
10 s
9
0 s
10 s
If the warning phase is set, the light flashes before
the door starts to move and during the actual travel
cycle. The factory setting is 1.
TAM: OPEN signal, when the door is not closed 24V
are available for signalling.
Menüstage 8: Door fitting
Press button
. "8" appears in the display.
The corresponding door type has to be chosen for an
ideal performance and for the optimisation of force.
Menu- Start
Stop
Start
value
open
open
closed closed
0
0
0
0
1
15
0
15
2
0
15
0
3
15
15
15
4
25
45
25
5
15
15
15
6
15
15
15
7
35
35
35
8
60
15
15
9
only smooth operation
These details correspond to the smooth operation
distance of the slide, measured in cm."
Important advice:
The factory-made adjustment of the value 4 should
be kept.
A modification of the soft operation distance is not
permissable unless official approval of the gate
manufacturer has been obtained.
Press button.
Subsequently press button
. "0" appears in the
display.
GB
pressed
24V
60 s
90 s
120 s
240 s
0 s
0 s
0 s
TAM
TAM
TAM
Stop
0
0
60
35
45
60
15
50
85