Astralpool 33556 Manual De Instalación Y De Mantenimiento página 24

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Once the water is mixed with the ozonated air, it returns to the general circuit for treatment of the pool water.
A mechanical system is positioned between the venturi and the Ozone Generator to ensure that water does not return to
the ozone generator. This system is known as the check valve safety kit (see Figure 5), and is composed of a check
valve and small cup which collects the water until it reaches the indicated level (about 350 mm of water gauge).
The kit operating principle is based on the differences between the liquid-gas densities, which prevents any water from the
venturi from flowing directly to the ozone generator by diverting it to the cup. The minimum height between the cup and the
tee must be about 1,700 mm.
The ozonated air outlet marked "out" is connected to the safety kit using 6*8 mm Teflon tubing, and from there to the
venturi.
FIG. 2
Ozonation equipment installation (without off-gassing chamber)
1
5
3
4
40
6 0
20
80
2
5
230 V ac
6
1. SAND SILEX FILTER
2. PRESSURE PUMP
3. INJECTOR 1"
4. PRESSURE GAUGE
5. PIPE PVC GLASS D32mm
6. SAFETY KIT, WATER TRAP
7. OZONE GENERATOR
Ref.: Ozone generator-AstralPool-gb-R11
7

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

33557335583355933560

Tabla de contenido