6.5. Maintenance of the off-gassing chamber
Check for off-gassing by inspecting all PVC glass (D32 mm) inlet and outlet tubes in the off-gassing chamber. In the inlet
tube, there should be numerous large bubbles as the result of water-ozonated air mixing by the venturi. In the outlet tube,
the water should have no large bubbles and the tube should be fully transparent.
The activated charcoal must be changed once a year.
Clean the filter (depending on the amount of accumulated dirt) located before the bleeder valve regularly.
Dismount the bleeder valve and clean it once a season. If necessary, replace worn parts (e.g., gaskets).
Keep the water level of the chamber at the second level (minimum), the maintenance level. If maintenance is not possible,
inspect and check that all equipment components are in good working condition.
7. EQUIPMENT START-UP
7.1 Normal running time
1. Open the ball valves of the general bypass (see Figures 2 and 3).
2. Start the pressure pump for the model.
Ozone Genetaror
Ozone Generator
Triox Spas/ Triox R-1
Triox R-2
70/5 (07946)
3. Gradually adjust the bypass valve where the venturi is located, until the pressure gauge indicates 3 to 4 bar (see
Figures 2 and 3).
4. Open the ozonated air valve.
5. Observe the air-water mixing in the transparent PVC glass tube of diameter 32 mm, to check that the venturi is
suctioning and working properly.
6. Check for voltage at the Ozone Generator equipment using the green indicator (2E) of Figure 7.
7. Check that air is reaching the Ozone Generator equipment by placing the hand near the air inlet (in). Check and make
sure that the pneumatic connections of the Teflon tube with the fittings are airtight.
8. Set the Ozone Generator equipment switches, ozone1 and ozone2 (Triox Spas only 1 switch). The respective
indicators should turn on immediately. For 100% duty, set both pushbuttons. For 50% duty, set only one pushbutton.
Ozone Generator
Triox R-3
Ozone Generator
Triox R-4
120/7 (07948)
70/7 (07947)