The pushbutton indicator does not turn on when the pushbutton is set.
The filter pump or pressure pump are not in the run position.
The indicator bulb is blown.
There is no ozone generation.
The equipment is not running.
One or both of the pushbuttons are not set.
The transformer coils (1l) (Fig. 8A, 8B, 9A, 9B) do not work.
One or more electrical components of the 3A POWER board (3L) or the 3B POWER board (3l) (Fig.
7A, 7B, 7C, 7D) is broken.
The dielectric-electrode assembly (Fig. 8A, 8B) of the ozone reactor (2l) is damaged.
The pressure pump does not work.
No power is being supplied to the pump.
The thermal relay trips due to an overload caused by a short circuit or similar fault.
The thermal protector has tripped due to an overload.
There is no air suction in the Ozone Generator equipment.
The pressure pump is not working.
There is insufficient pressure at the venturi inlet.
There is no water in the check valve safety kit (water trap).
The inlet valve for ozonated air to the venturi is closed.
The check valve of the venturi is clogged.
The pneumatic equipment is not airtight.
18
Ref.: Ozone generator-AstralPool-gb-R11