Fault Troubleshooting With Safe Solutions - Astralpool 33556 Manual De Instalación Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11. FAULT TROUBLESHOOTING WITH SAFE SOLUTIONS

FAUL T
The push-buttons used to stop the
Ozone Genera tor do not respond
The pump is not running.
The pump is not running, but the
breaker has not tripped.
The water circuit not containing O
is ruptured.
The water circuit containing O
is ruptured.
The water trap does not work.
The O circuit is ruptured.
3
The bypass outlet is clogged or
sluggish.
The automatic air bleeder
degasifier model) is clogged.
The GAC for the filter is depleted.
The venturi is clogged.
Water has entered the reactor.
HAZARD
None: T he pump c ontinues to operate
T he breaker switc h trips
A: Very little O comes out of the
3
Oxsan inlet. Saturation level:
20 g/m³ of O
3
B : Water has entered the reactor,
causing a short circuit.
O comes out of the Ozone Generator
3
3
inlet. Saturation level: 20 g/m³ of O
None detected.
3
O + H O losses
3
2
A: The trap fills with water up to
the reactor, causing a short circuit.
B : There is no water: The Ozone
Generator takes in air but does not mix
O ;hence, there is less O in the water.
3
O is expelled directly to the
3
atmosphere.
A)
No off-gassing chamber:
H O + O circuit
2
3
Low density, no suction:
reactor saturation
B 1)
Off-gassing chamber:
no water circulation or suction.
Increased level of gas in the water
chamber until ozonated water exits
at the highest concentration. O
bubbles and odor are observed. O
contamination
O contamination
3
No air suction: higher O concentration
The water causes a short circuit.
The pump heats up and can burn.
19
SAFE SOLUTION
Use the circuit breaker to stop the pump.
Notify Technical Service.
Use the breaker switch/thermal protector
to turn the O
In well-ventilated rooms with an air inlet and
outlet, any small leak is automatically destroyed
by air drafts before the maximum admissible
concentration is reached.
The O
equipment stops running.
Any small leak is automatically destroyed
by air drafts before the maximum admissible
3
concentration is reached.
Use well-ventilated rooms with air inlet
and outlet.
Hydraulic circuits: have an authorized
installer mount the system using standard
PVC materials.
The short circuit causes the Ozone Generator
to stop running due to a tripped breaker switch
or blown fuse.
Low O production.
3
Hydraulic circuits (pipes): have an authorized
installer mount the system using standard
PVC materials.
closed
Any small leak is automatically destroyed by
air drafts before the maximum admissible
concentration is reached.
Well-ventilated rooms with air inlet
.
and outlet.
there is
The Ozone Generator stops when the pump
stops.
Maintenance: check and clean the bleeder
regularly.
3
3
Maintenance: replace the GAC regularly .
Any small leak is automatically destroyed by
3
air drafts before the maximum admissible
concentration is reached.
Use well-ventilated rooms with air inlet
and outlet.
The breaker trips and the Ozone Generator unit
stops running.
Ref.: Ozone generator-AstralPool-gb-R11
zone Generator
unit off.
zone Generator
fuses trip and the
Non-hazardous situation.
3

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

33557335583355933560

Tabla de contenido