RIB K800 24V FCM FAST Manual Del Usuario página 36

Ocultar thumbs Ver también para K800 24V FCM FAST:
Tabla de contenido

Publicidad

G
B
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
(1000 CODES MAX) - with radio module ACG8069
ATTENTION: before storing the radio codes, use DIP 12 to select which transmitters to use:
DIP 12 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
SUN-PROX 2CH 2-channel - red keys and yellow led cod. ACG6220
SUN-PROX 4CH 4-channel - red keys and yellow led cod. ACG6224
DIP 12 ON (default): You can store transmitters with fixed code SUN and MOON:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056
SUN CLONE 4CH 4-channel - blue keys and yellow led cod. ACG6058
MOON 2CH 2-channel - black keys and yellow LED cod. ACG6081
MOON 4CH 4-channel - black keys and yellow LED cod. ACG6082
ATTENTION: it is not possible to memorize at the same time transmitters with fixed code and
transmitters with variable code.
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 seconds. If
the remote is memorized properly LED DL12 blinks green and a buzzer tone confirms
the correct memorization. The 10 seconds for programming the codes are automatically
renewed, with LED DL12 which flashes red, in order to store the next transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12
stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
ALL RADIO CODES FOR TOTAL OPENING CANCELLATION PROCEDURE
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - LED DL12 flashes red for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
green flashes of LED DL12 and 2 tones of the buzzer.
4 - LED DL12 flashes red again for 10 seonds and you can add new codes as shown above.
5 - Re-set DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR TOTAL OPENING)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The LED DL12 flashes green 6 times when the memory is full (1000 codes). Now LED
DL12 blinks red for 10 seconds enabling possible cancellation of all codes.
3 - Re-set DIP 1 to OFF and DIP 2 to OFF.
4 - End of procedure.
G - RADIO CODES PROGRAMMING PROCEDURE FOR PEDESTRIAN
OPENING (1000 CODES MAX) - with radio module ACG8069
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON. DL12 flashes green for 10 seconds.
2 - Press the transmitter button (usually channel B) within the allotted 10 seconds. If the
transmitter is properly memorized LED DL12 blinks red and the buzzer emits a tone. The
10 seconds are automatically renewed (DL12 flashes green) in order to memorize next
transmitter.
3 - To finish programming wait 10 seconds, or press the PROG button briefly. The LED DL12
stops flashing.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
ALL RADIO CODES FOR PEDESTRIAN OPENING CANCELLATION PROCEDURE
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON. LED DL12 flashes green for 10 seconds.
2 - Press and hold the PROG button for 5 seconds. Memory cancellation is indicated by two
red flashes of LED DL12 and two tones of the buzzer.
3 - The red LED DL1 remains active and you can add new codes as shown above.
4 - Reset DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR PEDESTRIAN OPENING)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - LED DL12 flashes green 6 times if the memory is full (1000 codes). LED DL12 blinks red
for 10 seconds enabling possible cancellation of codes.
3 - Set DIP 1 to OFF and DIP 3 to OFF.
4 - End of procedure.
H - PROGRAMMING RADIO CODES (FOR R-AUX RELAY) (1000 CODES MAX)
- with radio module ACG8069
* Remote control management can be enabled only by the RIB GATE app.
R-AUX normally works as a courtesy light for 3 minutes.
Through the RIB GATE app it is possible to configure the operation of this relay as
desired.
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON, DIP 2 to ON and then DIP 3 to ON. DL12 flashes orange for 10 seconds.
2 - Press the transmitter button (usually channel C) within the allotted 10 seconds. If the
transmitter is properly memorized LED DL12 blinks green and the buzzer emits a tone.
The 10 seconds are automatically renewed (DL12 flashes orange) in order to memorize
next transmitter.
3 - To finish programming wait 10 seconds, or press the PROG button briefly. The LED DL12
stops flashing.
4 - Reset DIP 1, 2 and 3 to OFF.
5 - End of procedure.
RADIO CODES CANCELLATION PROCEDURE (FOR R-AUX RELAY)
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON, DIP 2 to ON and then DIP 3 to ON. LED DL12 flashes green for 10
seconds.
2 - During these 10 seconds press and hold the PROG button for 5 seconds. Memory
cancellation is indicated by two green flashes of LED DL12 and two tones of the buzzer.
3 - LED DL12 blinks orange again for 10 seconds and you can add new codes as shown
above.
4 - Re-Set DIP 1, 2, 3 to OFF.
5 - End of procedure.
RADIO CODES MEMORY FULL INDICATOR (FOR R-AUX RELAY)
Indication is visible only when gate is stationary.
1 - Set DIP 1 to ON, DIP 2 to ON and then DIP 3 to ON.
2 - LED DL12 flashes green 6 times if the memory is full (1000 codes). LED DL12 blinks red
for 10 seconds enabling possible cancellation of codes.
3 - Re-Set DIP 1, 2, 3 to OFF.
4 - End of procedure.
OPERATION OF CONTROL ACCESSORIES
OPENING BUTTON (COM A+/OPEN)
When the gate is at a standstill, the button controls the opening movement. If pressed during
closing, the gate will re-open.
OPENING BUTTON WITH CLOCK FUNCTION (COM A+/B.I.O.)
The clock function is useful during rush hours, when vehicle traffic is slow (e.g. entrance/exit
of workers, emergencies in residential areas, parking lots, etc.).
By connecting a switch and/or a daily/weekly clock to the "COM A+/B.I.O." terminals, you
can open the gate (and keep it open) until the switch or clock remain enabled.
All command functions are inhibited with open automation.
When releasing the switch, or once the set time has lapsed, the automation will shut down
instantly.
CLOSING BUTTON (COM A+/CLOSE)
When the gate is at a standstill, the button controls the closing movement.
SINGLE CONTROL BUTTON (COM A+/START)
If DIP 6 is set to ON = > it runs a command sequence open-stop-close-stop-open etc.
If DIP 6 is set to OFF = > it opens the closed gate. If operated while the gate is opening, the
button has no effect. If operated with the gate open, it closes the
gate. If operated while the gate is closing, it re-opens the gate.
REMOTE CONTROL FOR BOTH FULL AND PEDESTRIAN OPENING
If DIP 6 is set to ON = > it runs a cyclical command sequence open-stop-close-stop-open
etc.
If DIP 6 is set to OFF = > it opens the closed gate. If operated while the gate is opening, the
button has no effect. If operated with the gate open, it closes the
gate. If operated while the gate is closing, it re-opens the gate.
36

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aa31134

Tabla de contenido