MAINTENANCE / RECOMMENDATIONS
1 - Air filter maintenance:
• It is necessary to periodically empty the air filter. To do so, press and hold the orange button below the filter.
• Disassembly:
- Unplug the air supply.
- Grab the tank, press the latch and rotate the bowl 45 degrees to the left.
- Pull the cube downwards and then put it down .
- The filtering part is white, clean or replace it if necessary (ref. 039735).
2 - Periodical maintenance:
• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections checked by a qualified person, with an
insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, an after sales
service or a qualified person to prevent danger.
• Do not obstruct the machine's air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During set up, the operator must
ensure that the machine is unplugged. Connecting generators in a series or a parallel circuit is forbidden. It is recommended to use the welding cables
supplied with the unit in order to obtain the optimum product settings.
MACHINE SUPPLIED WITH
Starting kit
Pneumatic fittings
HARDWARE DESCRIPTION (FIG-1)
1-
Keyboard + buttons
2-
Torch connector
3-
Earth clamp connector
4-
Compressed air connector
CONTROL BOARD (IHM) (FIG-2)
1-
Air pressure adjustment knob.
2-
Air pressure setting selection button (manual / auto).
3-
Current setting knob.
4-
Operating mode selector.
POWER SUPPLY – STARTING UP
- The PLASMA CUTTER 85A is supplied with a 32A plug of type EN 60309-1.
- The PLASMA CUTTER 125A is supplied without plug, it is recommended to use a 63A plug of type EN 60309-1.
These current sources should only be used on a four-wire, three-phase 400V (50-60 Hz) electrical installation with a neutral connected to earth.
The effective absorbed current (I1eff) is indicated on the device, for maximum operating conditions. Check that the power supply and its protections
(fuse and/or circuit breaker) are compatible with the current required in use. In some countries, it may be necessary to change the plug to allow use
at maximum conditions.
20
PLASMA CUTTER 85A / 125A
- Maintenance should only be carried out by a qualified person. An annual maintenance is recommended.
- Disconnect the power supply by unplugging the plug, and wait two minutes before working on the equipment. Inside, voltages
and intensities are high and dangerous.
CUTTER 85A TRI
Ref. 029880
-
4 m - 10 mm²
-
8 mm + 10 mm
Ref. 029996
Ref. 029897
MT 125 - 6m
4 m - 10 mm²
4 m - 16 mm²
8 mm + 10 mm
8 mm + 10 mm
5-
Air filter
6-
On/off switch
7-
Power supply cable
8-
CNC connector (optional)
5-
Operating modes.
6-
Air pressure display.
7-
Electrical current display.
CUTTER 125A TRI
Ref. 029910
-
MT 125 - 6m
4 m - 16 mm²
-
8 mm + 10 mm
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plasma cutter 125a

Tabla de contenido