PLASMA CUTTER 85A / 125A
EN
3 - INSTALLATION OF THE MANUAL TORCH CONSUMABLES :
Before changing the consumables, cut the power supply using the interrupor behind the machine.
To use the manual torch, a complete set of consumables must be installed in the correct order: diffuser, electrode, tailpipe, protection shroud and
shield.
Shield
Protective shroud
Tailpipe
Electrode
Diffuser
Torch
AUTOMATIC TORCH SETUP (REF. 040014)
1 - CHOICE OF CONSUMABLES
The auto torch uses «unprotected» consumables, a small distance distance (2 to 3 mm, between the torch and the metal).
To maximise the cutting performance, it is important to use the correct consumables depending on the plasma cutter settings.
• A current that is too low leads to low cutting performance.
• A current that is too high for the tailpipe leads to early deterioration.
Gouging is impossible with an automatic torch.