Troubleshooting

Clean the condensate drain when necessary. If it is blocked, the condensate
collects on the bottom of the minibar.
➤ For absorber versions: Use a brush or soft cloth to remove dust from the
absorber unit on a yearly basis.
A
NOTICE! Damage hazard
The lamp can only be replaced by the manufacturer, a service agent or
similarly qualified person to avoid hazard.
9
Troubleshooting
Fault
Not cooling
Not cooling, interior
light continuously flash-
ing
16
Possible cause
Power plug not plugged in
No voltage at socket
Electronics or sensors defective
For versions with absorber
cooling: Heating cartridge defective
Auto-defrost active (see chapter
"Defrosting" on page 15)
Minibar recently switched on
Cooling unit defective
Cooling unit blocked
Cooling unit not water-tight
Heating element defective
Error during self-test
HiPro
Solution
Insert power plug into
socket
Check circuit breaker
Contact service agent.
Service agent: Install new
electronics or sensor
Contact service agent.
Service agent: Install new
heating cartridge
No action required
Check cooling again after
5 to 6 hours
Contact service agent.
Service agent: Replace
minibar
Contact service agent.
EN