10.2 METROLOGICAL DETAILS
Reference conditions: 18°C - 28°C; RH < 80%, no condensation.
Norm: NF EN 61010-1, 300V. Protection: 600V CAT III
CM685
CM660/670
mA
40/400/1000
Resolution (A)
0.01/0.1/1
Accuracy
±1.5%+8dgt/1.0+5/1.0+5
In max (A)
1100
mA
40/400/1000
Resolution (A)
0.01/0.1/1
Accuracy
±1.5%+8dgt/1.0+5/1.0+5
mV
4/40/400/600
Resolution (V)
0.001/0,01/0.1/1
Accuracy
±0.75 %+2 dgt
11 /10/10/10
R. in (MΩ)
MV
4/40/400/600
Resolution (V)
0.001/0,01/0.1/1
Accuracy
±1% +5 dgt
11 /10/10/10 < 50 pF
R. in (MΩ)
Ω
400/4K/40K/400K/4M/40M
Resolution (Ω)
0,1 /1/10/100/1K/10K
I in (<)
1 mA/0.5mA/70µA/7µA/0.7mA/70nA
Accuracy
±0.9%+2pt/0.9+2/0.9+2/2+2/5+2
Ω
400
Resolution
0.1 Ω.
Buzzer: <50Ω ±25Ω. U circuit open <3,4 V
Hz
400/4000
Resolution
0.1 / 1 Hz
Accuracy
±0.5 %, 5 dgt
U
<3.4V
TEMP
°C (°F)
--50
1100°C (-35
2012°F)
°C°F
-50
436.9°C (-35
274.7°F)
Resolution
1°C (2°F) / 0,1°C (0.2°F)
Accuracy
±1 % + 5 dgt
True
Yes
CM660: No
RMS
CM670: Yes
Yes
No
30
.