EMERGENCY DEAD MAN OPERATION

This operational mode can be used to move the gate in DEAD
MAN mode in particular cases, such as installation/maintenance or
in the case of malfunctioning of photocell, edge, limit switches or
encoder.
To activate the function the START command must be pressed
3 times (presses must last at least 1 second; the pause between
commands must last at least 1 second).
1"
1"
>1"
The fourth START command activates the gate in MAN PRESENT
mode. To move the gate keep the START command pressed for
the duration of the operation (time T).
The function will automatically turn off after 10 seconds of
inactivity of the gate.
STORING OF THE TRANSMITTERS
NOTE: the first remote control to be memorised determines the
mode of operation; Royal or Personal Pass.
To change the operating mode, it is essential to perform a FULL
CODE ERASING and then memorise the new remote control.
1. Keep PROG key pressed until the led RX lightens
2. Release the PROG key
3. Within 5 seconds, press and hold the button on the remote
control.
- if the remote control unit is a ROYAL version, the procedure
ends at point 4
- if the remote control unit is a PERSONAL PASS version, go
to point 5 and follow the procedure until the end of the
section
4. Led RX is turned off to indicate the code has been memorised
correctly
5. The led RX goes out and goes on again: the code has been
memorised and the control unit remains standby for 5 s with a
new code to be memorised
6. Memorise all the remote control necessary
7. After 5 seconds without a valid transmission, the led is turned
off and the control unit returns to normal operating mode
1"
T
>1"
>1"
REMOTE RADIO LEARNING
(Personal Pass system only)
This procedure allows to memorize new transmitters by radio.
The transmitter which allows to enable the programming
by radio must be memorized in advance.
1. Press for at least 5 seconds the keys 1+2 or 1+3 of one
transmitter that is already saved
2. Release both keys
3. Press, within 5 seconds, the key of the new transmitter that
you intend to save
4. Release the key and repeat the procedure for the other keys of
the remote control or with other radio controls to be saved
ROLLING CODE MODE
(Personal Pass system only)
This function is enabled by default.
1. Press PROG push-button, holding it for 8 seconds
2. The led RX will switch off after 8 seconds. Release the
push-button
3. The led starts a sequence of flashing for 5 seconds:
Single flashings: ROLLING CODE is disabled
Double flashings: ROLLING CODE is enabled
4. To modify the parameters press the PROG push-button within
5 seconds after the first flashing of the sequence; the led will
flash according to the new parameters.
5. After 5 seconds, the led turns off and the control unit moves
back to normal operation
FULL CODE ERASING
To perform a full code erasing do the following:
1. Remove the power to the control unit
2. By holding the key PROG of the receiver pressed, you will
reactivate the power supply.
The led RX goes on: release the PROG key
3. The memory spaces are empty and available for a new
programming: the first remote control to be memorised
determines the mode of operation; Royal or Personal Pass
- 12 -