Maintaining the Escape Hood
Check that the adjusting buckle slides easily,
allowing full adjustment of the strap.
4. Inspect the Cylinder Valve
a. Look for broken or bent parts on the handwheel
and pressure gauge.
b. Open and close the valve to be sure it works properly.
c. Inspect the pressure gauge:
The lens must not be cracked or broken.
The gauge face must be visible without distortion.
The gauge needle must operate.
5. Inspect the cylinder at least monthly or before each use,
to be sure it is FULL (2216 or 3000 psi on the pressure
gauge).
Hood Packing Instructions for TransAire Apparatus
1. Lay the hood flat and fold in thirds lengthwise.
12
2. Fold the top third of the hood over.).
3. Put the hood inlet assembly outside of the hood.
4. Place the hood into the pouch on the carrier by first
inserting the tube into the pouch, followed by the fold-
ed hood. Leave the hood inlet assembly exposed.
TAL 0110 (L) Rev. 2 - 10008901